A password is required on connection to protect the hygiene flush against mani-
pulation. The password (= serial number) is located on the rating plate of the
hygiene flush in the cistern. The password is stored automatically to prevent the
need for repeated input.
Practical tip:
The assembly instructions come with a sticker on which you can note the
password and affix in a suitable place (e.g. splash guard). This makes it easier
to find the password the next time you need it.
SN 1234
Hygienespülung
DMF: 13/19
Position of the password on the rating plate of the hygiene flush unit
Practical tip:
Change the name of the device immediately following initial connection with
the hygiene flush to ensure subsequent allocation. If multiple new hygiene
flushes are installed in a building these should be put into operation one after
another. This allows clear allocation prior to renaming.
Factory settings
If the hygiene flush is not programmed, it will work on the following factory set-
tings after initial operation:
Valve allocation
Cold flush programme
Warm flush programme
Hygiene flush factory settings
12 V
max. 9 W
www.tece.com
IP 67
Cold + warm
Interval flush
Interval 72 h, flush volume 10 litres
Interval flush
Interval 72 h, flush volume 5 litres