TECE TECEprofil WC-Modul Instrucciones De Uso página 26

Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 67
Flush programmes
The flush programmes can be easily adjusted via the app to the conditions of
the building or the potable water installation. You can select from two program-
EN
mes as required: Interval or weekday programme (see all installation examples).
Interval flush programme
Setting of a time interval after which the hygiene flush initiates a water
exchange.
The same interval or two different intervals can be set for both water connec-
tions.
The same flush volume or two different flush volumes can be set for both
water connections.
Weekday flush programme
Selection of the weekdays to be flushed.
You can select a time for activating the flush.
The same flush volume or two different flush volumes can be set for both
water connections.
The programmes will start once loaded on the electronics. Once the test envi-
ronment is activated, you can get to know the app and test out the functions,
even if there is no hygiene flush in range.
Practical tip:
You can store flush programmes in the app and thus use them multiple times.
This always offers an advantage when a building contains rooms of the same
type (e.g. hotel). Additionally, flush programmes can be pre-programmed from
the office and simply need to be loaded on the construction site.
Usage recognition
Usage recognition prevents the unnecessary flushing of potable water. If the
toilet is used and water is consumed, the fill level sensor recognises this and
resets the interval or weekday. The interval set in the interval flush programme
will then start from the beginning, while the flush set for the day in the weekday
flush programme will be skipped.
Level sensor:
The level sensor monitors the water level and protects against overfilling of the
cistern. If, in the event of a malfunction, the water in the cistern rises to the point
that there is a risk of overflowing, this is detected by the level sensor and the
flushing process stops.
26
Tabla de contenido
loading

Productos relacionados para TECE TECEprofil WC-Modul

Tabla de contenido