Spare Parts; Decommissioning; Disassembly And Replacement; Preparing The Product For Storage/Later Use - Bosch Rexroth HD 2 Instrucciones De Montaje

Ocultar thumbs Ver también para Rexroth HD 2:
Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 155

10.5 Spare parts

For a list of spare parts, see spare parts list in MTpro, 3 842 539 057
(download: www.boschrexroth.com/mtpro).

11 Decommissioning

This product is a component which does not need to be decommissioned.
Accordingly, this section has been left blank.

12 Disassembly and replacement

High electrical voltage!
Risk of severe injury or death from electric shock.
Disconnect the relevant system component before performing any maintenance
or repair work.
Secure the system against being switched back on unintentionally.
High pneumatic pressure!
Risk of severe injury or death.
Switch off the compressed air supply to the relevant system component before
performing any maintenance or repair work.
Secure the system against being switched back on unintentionally.
Suspended loads can fall!
Falling objects can result in severe injury (or even death).
Use only slings with suffi ciently high bearing loads (for product weight,
see delivery documents).
Make sure the lifting straps are correctly fastened before lifting the product.
Secure the product against tipping over when lifting!
Make sure that no one but the operator is in the danger zone during lifting and
lowering!

12.1 Preparing the product for storage/later use

• Only set the product down on a fl at surface.
• Protect the product from mechanical stress.
• Protect the product from environmental infl uences, such as dirt and moisture.
• Observe the ambient conditions, see page 37.
• For products with a mounted motor: support the product so that the motor is not
placed under mechanical load.
Decommissioning
WARNING
3 842 358 735/2019-10, MIT: HD 2, Bosch Rexroth AG
35/38
Tabla de contenido
loading

Este manual también es adecuado para:

3 842 999 848

Tabla de contenido