Section 3
Ice Bin Level Sensor
Ice bin sensor is an optional accessory that allows the ice
level in the bin to be set to one of three different levels. The
bin level can be set seasonally to match usage, which results
in lower energy costs and fresher ice.
1. In the Energy Saver menu, ensure that Ice Program is
highlighted and press checkmark.
2. Select Bin Level and press checkmark.
3. Select Settings and press checkmark.
4. On this screen you can choose to set the ice level to low,
medium or high by highlighting your choice and pressing
the Checkmark. Selecting one will deselect the other.
NOTE: On ice beverage models you must choose low for
the control to function. The ice beverage sensor has one
thermistor, while the bin level sensor has three.
5. Select - Exit, Save changes, Yes and then Done.
When the check reflects your preference, use the Down to
navigate to Exit and press the Checkmark. The display will
return to the Set-up menu.
Water Miser
Water Miser is a feature that reduces water usage by
eliminating flush cycles. Enabling this feature is only
recommended for systems with de-ionized or reverse
osmosis filtering.
1. From the Energy Saver menu, use the Down arrow to
highlight Water Miser.
2. Press the Checkmark. On this screen, you can choose
to turn the Water Miser ON or OFF by highlighting your
choice and pressing the Checkmark. Selecting one will
deselect the other.
3. Press the Left arrow to return to previous screens and to
the Energy Saver menu.
Part Number: 000013325 Rev 02 6/17
Statistics
1. From the Energy Saver menu, use the Down arrow to
highlight Statistics.
2. Press the Checkmark. Choose to view ice production,
potable water usage or energy usage statistics by
highlighting your choice and pressing the Checkmark.
3. Press the Left arrow to return to previous screens and to
the Energy Saver menu.
Factory Defaults
The entire setup can be reset to the factory defaults.
1. From the Set-Up menu, use the Down arrow to highlight
Fact Default.
2. Press the Checkmark two times to reset the ice machine.
The display will return to the Set-Up menu.
Operation
35