used solely for that equipment. It is advisable to add a
25 A fuse in a 12 Volt system, and a 15 A fuse in a 24 Volt
system.
DANGER
Fire hazard.
Use only recommended circuit breakers and
fuses.
4.4.1 Advice for wiring up
12 V
Electric
1.5 mm
= 3 ft 3 in max
2
diameter
2.5 mm
= 6 ft 7 in max
2
wire
4 mm
= 9 ft 10 in max
2
6 mm
= 14 ft 1 in max
2
4.4.2 Fitting the Control Box
• Fix the control box in a dry, protected location.
• Connect the cable from the control panel to the control box.
DANGER
Electrical hazards.
Do not connect battery, power source
in to the control panel.
• Insert and connect the electrical wiring from the
the electrical box.
• Lastly, connect the electrical box to the battery, making
sure that the cross-section of the wires is sufficient.
NOTICE
Make sure the wires are connected correctly as
shown pg.
, always observing the colours.
7
4.4.3 Connection of the tank sensors (see diagrams 9 and 10)
Fitting
Sensors are provided with 14'' cables. You can extend up to
15 ft; no specific wire is required.
Locate the location for the sensors using diagram 9 and the
information below:
- The Full Tank sensor should be placed at the minimum dis-
tance of «wall thickness + 50% of thickness» from the top
edge.
- The Mid-Tank sensor should be installed in the middle of the
tank, both in height and width.
- Clearance should be no less than 2''.
Clean the surface of the tank. Firmly press the sensor on the
tank to stick it in place.
IMPORTANT
There can not be any metallic part or another water tank
within the clearance section of each sensor. This can affect
its sensitivity creating a false reading.
There shouldn't be another cable, sensor or any wire above
our sensors.
Optional : you can use a second set of sensor. Please respect
clearance between sensors.
Connection to the Control Box
Sensors are not polarized.
POWER ON
Follow the wiring diagrams on pg.
Return wire has to be plugged on negative terminal of control
box or on ground metal frame (ground continuity has to be
checked first).
5. COMMISSIONING
5.1 SENSOR SETUP
Before normal use, set up the black tank sensor system once
the sensor installation and wiring are complete.
Important : Have to be done with empty tank.
• Turn ON power.
• Press "NORMAL" and "EMPTY" in the Control Panel for
more than 5 seconds.
24 V
1.5 mm
= 11 ft 6 in max
2
2.5 mm
= 19 ft 8 in max
2
4 mm
= 31 ft 2 in max
2
6 mm
= 45 ft 11 in max
2
to
SN4 071
POWER ON
POWER ON
7
5.2 FUNCTIONAL TEST
Open the water admission valve fully to ensure a good
bowl rinse.
Normal cycle test
• Press pushbutton «NORMAL».
The cycle lasts 15 seconds, during which the bowl fills with
water. At the 7th second, the pump also starts running briefly
and then again twice.
Eco cycle test :
• Press pushbutton «ECO».
The pump switches on once and the bowl fills up for 12 se-
conds. The pump starts again during the last 3 seconds.
Repeat cycle tests again.
Important: Make sure that there are no leaks in all the water
lines.
6. USE
must only be used for shredding and disposing of
SN4 071
feaces and toilet paper.
Only the disposal of toilet papers, fecal matter, and waste
water will be under guarantee. Any damage due to foreign
bodies such as cotton, condoms, sanitary towels, wet wipes
food, hair, or liquids such as oils, solvent products,... will not
be under guarantee.
NOTICE
If away for a long period (holiday,...) or in the
event of a long interruption of electricity, the water
and electricity supplies to the
switched off (see 7.1 WINTERING).
6.1 CONTROL PANEL OPERATION
6.1.1 Flush modes
Normal Cycle
Recommended for flushing solids and
toilet paper.
Press «NORMAL» button.
The cycle is 15 s long.
POWER ON
Eco Cycle
Recommended for flushing liquids and
small amounts of toilet paper.
Press «ECO» button.
The cycle is 13 s long.
POWER ON
Empty bowl Cycle
POWER ON
Note: No use is possible when the black water tank is full (see
6.2 Management of the Black water tank)
6.1.2 Program mode
Adjustment of the rinsing cycle: The rinsing time during the
"Normal" cycle can be programmed to increase up to 8 more
seconds. The cycle will increase from 15 to 23 seconds.
To enter the programming mode:
• Press the «NORMAL» and «ECO» buttons at the same time
for at least 5 seconds. The red LED flashes for 5 seconds and
then goes off.
9
should be
SN4 071
POWER ON
POWER ON
Recommended for removing water
from the bowl.
Press «EMPTY» button until the wa-
ter reaches its minimum level in the
bowl.
Note: Remains of water are always
present as its required for the trap.
Press the «NORMAL» or «ECO» but-
ton to return to normal operation.
EN-US
POWER ON