Electricity Supply - Lavorwash Advanced Warm up King Manual De Instrucciones

Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 34
onto the water connection of the unit.
· Hang the filter in the container.
· Vent the unit before operation.
· Unscrew the high-pressure line at the high-
pressure outlet of the unit.
· Switch on the unit and let it run until water free of
bubbles emerges at the high-pressure outlet.
· Switch off the unit and screw on the high-pressure
hose again.
Failure to comply with the above conditions
causes serious mechanical damage to the
pump and the loss of warranty cover.
> ELECTRICITY SUPPLY
- The appliance's electrical connection must
comply with the IEC 60364-1 standard.
IMPORTANT: Before
appliance, make sure that the nameplate
data are the same as those of the electrical
mains and that the socket is protected by a
differential security breaker with tripping
sensitivity below 0.03 A - 30 ms.
- If the appliance's plug is not compatible with
the socket, have the socket replaced with
another of suitable type by professionally
qualified staff.
- Never use the appliance in ambient
temperatures below 0° C if it is equipped
with a PVC (H VV-F) cable.
• XY WARNING: Inadequate extension cords
can be dangerous.
• XJ WARNING: If an extension cord is used,
the plug and socket must be of watertight
construction.
Information for supply may also be obtained
from the plug manufacturer.
<16 A
<20 m
ø 1,5 mm
14 AWG
20 m - 50 m ø 2,5 mm
12 AWG
> PLUG
HOW TO CONNECT THE CORD TO A U.K. PLUG:
IMPORTANT The wires in the mains lead are
coloured in accordance with the following code:
Blue
Brown
Yellow/Green
Please read the instructions given below before
connecting
the
<25 A
ø 2,5 mm
2
2
12 AWG
ø 4,0 mm
2
2
10 AWG
Neutral
Live
Earth
connecting the cord
to a plug. If in doubt
please consult a qua-
lified electrician. As
the colours of the
wires in the mains
lead of this appliance
may not correspond
with the coloured
markings identifying
the terminals in your
plug, proceed as fol-
lows: The wires that is
coloured Brown must
be connected to the terminal which is marked with
the letter L or coloured Red. The wire that is colou-
red Blue must be connected to the terminal wich is
marked with the letter N or coloured Black. Safety
points for rewireable or moulded plug: The mains
lead of this appliance may be already fitted with a
BS1363 13A plug.
- If your socket outlet is not suitable for the plug,
then the plug must be removed (cut off if it is a
moulded on plug), the flexible cord insulation
should be stripped back as appropriate and a
suitable 3 pin plug fitted.
• WARNING: Dispose of a plug that has been cut
from the power supply cord, as such a plug is
hazardous if inserted in a live 13A socket outlet
elsewhere in the house. - Should the fuse need
to be replaced an ASTA marked fuse, approved
to BS1362, of the same rating must be used. -
Always replace the fuse cover after fitting a fuse.
The plug must NOT be used if the cover is omitted
or lost until a replacement is obtained. - Make
certain that only the correct fuse cover is used
and fitted. - For plugs with detachable fuse cover
the replacement must be the same as the colour
insert in the base of the plug, or as directed by the
embossed wording on the base of the plug. - If
the detachable fuse cover is lost a replacement
may be purchased from a Service Centre.
T.S. ( if fitted)
NOTE: T.S. (Automatic Stop System), which
stops the machine during the bypass phase. To
start the water cleaner, it is therefore necessary to
set the switch on position (I)"ON"; after that press
the pistol trigger: the Automatic Stop System will
start the machine and will stop it automatically
EN
4 -
4 -
19
Tabla de contenido
loading