· Vent the unit before operation.
· Unscrew the high-pressure line at the high-pressure
outlet of the unit.
· Switch on the unit and let it run until water free of
bubbles emerges at the high-pressure outlet.
· Switch off the unit and screw on the high-pressure
hose again.
Failure to comply with the above conditions
causes serious mechanical damage to the
pump and the loss of warranty cover.
> ELECTRICITY SUPPLY
- The appliance's electrical connection must
comply with the IEC 60364-1 standard.
IMPORTANT: Before connecting the ap-
pliance, make sure that the nameplate data
are the same as those of the electrical mains
and that the socket is protected by a differ-
ential security breaker with tripping sensitiv-
ity below 0.03 A - 30 ms.
- If the appliance's plug is not compatible
with the socket, have the socket replaced
with another of suitable type by profession-
ally qualified staff.
- Never use the appliance in ambient temper-
atures below 0° C if it is equipped with a PVC
(H VV-F) cable.
• XY WARNING: Inadequate extension cords
can be dangerous.
• XJ WARNING: If an extension cord is used,
the plug and socket must be of watertight
construction.
Information for supply may also be obtained
from the plug manufacturer.
<16 A
<20 m
ø 1,5 mm
14 AWG
20 m - 50 m ø 2,5 mm
12 AWG
> PLUG
HOW TO CONNECT THE CORD TO A U.K. PLUG:
IMPORTANT The wires in the mains lead are col-
oured in accordance with the following code:
Blue
Brown
Yellow/Green
Please read the instructions given below before con-
necting the cord to a plug. If in doubt please consult
<25 A
ø 2,5 mm
2
2
12 AWG
ø 4,0 mm
2
2
10 AWG
Neutral
Live
Earth
a qualified electrician.
As the colours of the
wires in the mains
lead of this appliance
may not correspond
with the coloured
markings identifying
the terminals in your
plug, proceed as fol-
lows: The wires that is
coloured Brown must
be connected to the
terminal
which
is
marked with the let-
ter L or coloured Red. The wire that is coloured Blue
must be connected to the terminal wich is marked
with the letter N or coloured Black. Safety points for
rewireable or moulded plug: The mains lead of this
appliance may be already fitted with a BS1363 13A
plug.
- If your socket outlet is not suitable for the plug, then
the plug must be removed (cut off if it is a mould-
ed on plug), the flexible cord insulation should be
stripped back as appropriate and a suitable 3 pin
plug fitted.
• WARNING: Dispose of a plug that has been cut from
the power supply cord, as such a plug is hazardous
if inserted in a live 13A socket outlet elsewhere in
the house. - Should the fuse need to be replaced
an ASTA marked fuse, approved to BS1362, of the
same rating must be used. - Always replace the fuse
cover after fitting a fuse. The plug must NOT be used
if the cover is omitted or lost until a replacement is
obtained. - Make certain that only the correct fuse
cover is used and fitted. - For plugs with detachable
fuse cover the replacement must be the same as the
colour insert in the base of the plug, or as directed by
the embossed wording on the base of the plug. - If
the detachable fuse cover is lost a replacement may
be purchased from a Service Centre.
( if fitted)
NOTE:
which stops the machine during the bypass phase.
To start the water cleaner, it is therefore necessary to
set the switch on position (I)"ON"; after that press the
pistol trigger: the Automatic Stop System will start
the machine and will stop it automatically when
the trigger is released. It is advisable to put on the
safety of the pistol trigger whenever the machine is
stopped, in order to avoid unintentional starting.