Toshiba RAV-GM901UTP-E Manual Del Usuario página 72

Ocultar thumbs Ver también para RAV-GM901UTP-E:
Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 23
Wired
Wireless remote controller
remote
Sensor block display of
controller
receiving unit
display
Main defective parts
Operation Timer
Indication
Ready
Flashing
GR GR OR
Gas leakage
P15
ALT
detected
P19
ALT
4-way valve error
High-pressure
P20
ALT
protective operation
Outdoor unit fan
P22
ALT
error
Outdoor unit inverter
P26
ALT
Idc activated
Outdoor unit position
P29
ALT
error
Other indoor unit
P31
ALT
error
: Lighting
: Flashing
: OFF
: The air conditioner automatically enters the auto-address setting mode.
ALT: When two LEDs are flashing, they flash alternately. SIM: When two LEDs are flashing, they flash in synchronization. Receiving unit
display OR: Orange GR: Green
141-EN
Judging
Parts to be checked / error description
device
There may be gas leakage from the pipe or
Outdoor
connecting part. Check for gas leakage.
4-way valve, indoor temp. sensors (TC/TCJ)
Outdoor
--- An error was detected due to temperature
(Indoor)
drop of the indoor unit heat exchanger sensor
when heating.
Outdoor
High-pressure protection
Outdoor unit fan motor, outdoor unit P.C. board
Outdoor
--- An error (overcurrent, locking, etc.) was
detected in the outdoor unit fan drive circuit.
IGBT, outdoor unit P.C. board, inverter wiring,
Outdoor
compressor --- Short-circuit protection for compressor
drive circuit devices (G-Tr/IGBT) was activated.
Outdoor unit P.C. board, high-pressure switch ---
Outdoor
Compressor motor position error was detected.
Another indoor unit in the group is raising an alarm.
Indoor
E03/L07/L03/L08 alarm check locations and error
description
– 71 –
Air
conditioner
status
Entire
stop
Auto-
reset
Entire
stop
Entire
stop
Entire
stop
Entire
stop
Entire
stop
Auto-
reset
142-EN