Description Of Operation - Porter Cable CPLMC7580V2C Manual De Instrucciones

Ocultar thumbs Ver también para CPLMC7580V2C:
Tabla de contenido
Idiomas disponibles

Idiomas disponibles

All manuals and user guides at all-guides.com
kNOW YOUR AIR COMPRESSOR
READ THIS OWNER'S MANUAL AND SAFETY RULES BEFORE OPERATING
YOUR UNIT. Compare the illustrations with your unit to familiarize yourself with
the location of various controls and adjustments. Save this manual for future
reference.
Tank
Pressure
Gauge
Pressure
Switch

DESCRIPTION OF OPERATION

Become familiar with these controls
before operating the unit.
On/Auto(I)/Off(O) Switch: Turn this
switch "On/Auto(I)" to provide auto-
matic power to the pressure switch and
"Off(O)" to remove power at the end of
each use.
Pressure Switch: The pressure switch
automatically starts the motor when
the air tank pressure drops below the
factory set "cut-in" pressure. It stops
the motor when the air tank pressure
reaches the factory set "cut-out" pres-
sure.
Safety Valve: If the pressure switch
does not shut off the air compressor
at its "cut-out" pressure setting, the
safety valve will protect against high
pressure by "popping out" at its factory
set pressure (slightly higher than the
pressure switch "cut-out" setting).
Tank Pressure Gauge: The tank pres-
sure gauge indicates the reserve air
pressure in the tank.
Globe Valve: Opens and closes air
discharge valve. Turn knob counter-
clockwise to open and clockwise to
close.
1000003910
OPERATION
On/Auto(I)/Off(O) Switch
Safety Valve
Regulator (sold separately, not
shown): An air pressure regulator or a
separate air transformer which com-
bines the functions of air regulation
and/or moisture and dirt removal is rec-
ommended for most applications.
Cooling System (not shown): This
compressor contains an advanced
design cooling system. At the heart of
this cooling system is an engineered
fan. It is perfectly normal for this fan to
blow air through the vent holes in large
amounts. You know that the cooling
system is working when air is being
expelled.
Air Compressor Pump (not shown):
Compresses air into the air tank. Working
air is not available until the compressor
has raised the air tank pressure above
that required at the air outlet.
Drain Valve:The drain valve is located
at the base of the air tank and is used
to drain condensation at the end of
each use.
Drain
Valve
12 - ENG
Globe Valve
Tabla de contenido
loading

Tabla de contenido