Dometic WAECO CoolMatic HDC195 Instrucciones De Montaje Y De Uso página 55

Nevera con compresor
Ocultar thumbs Ver también para WAECO CoolMatic HDC195:
Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 305
HDC195, HDC225
Interior temperature too low at control level "1"
Fault
Compressor runs
constantly
Compressor runs for a
long time
Poor cooling, increase in interior temperature
Fault
Compressor runs for a
long time/continuously
Compressor does not
run often
EN
All manuals and user guides at all-guides.com
Possible cause
Thermostat sensor has no contact to
the vaporiser
Short circuit in the thermostat line
Thermostat defective
Large quantities have been frozen in
the freezer compartment
Possible cause
Vaporiser is iced over
Ambient temperature too high
Insufficient ventilation
Condenser is dirty
Fan defective (if installed)
Battery capacity exhausted
Troubleshooting
Remedy
Secure the sensor
Change the thermostat
Remedy
Defrost the vaporiser
Move the refrigerator to
another location
Clean the condenser
Replace the fan
Charge the battery
55
Tabla de contenido

Solución de problemas

loading

Este manual también es adecuado para:

Waeco coolmatic hdc 225

Tabla de contenido