8.1.9 Changing Parameters at the Special Level (C) in the DA40MS02 Controls.

Avtivating the special level (programming level C).
Prerequisite: The parameter 798 at the mechanic level (B) is set to I (<798> = I). See
Chapter 8.1.8
Turn the mains switch off and, after approx. 2 sec., on again. The special level C is
activated.
The setting of the parameters and the parameter values occurs in the same manner as
at the mechanic level. See Chapter 8.1.8
The special level C is exited again by turning off the mains switch.
Note
The special level C contains all parameters (including those at levels A and B).

8.1.10 Checking and Setting the Positions at the DA40MS02 Controls

Checking and setting the reference position
Activate the mechanic level (B). See Chapter 8.1.8
Call up parameter 700.
Tap the pedal forward briefly, the machine starts and positions in the reference
position which corresponds to position "F" of the handwheel.
Is the handwheel in position "F"?
-
If not, then the handwheel must be turned to position "F".
-
Tap the pedal forward. The machine makes one revolution and
positions in the corrected position.
-
The position can be corrected repeatedly.
If no further correction is required, exit the mechanic level or call up the next
parameter, the reference position is saved.
ATTENTION!
This level contains control parameters whose values must
only be changed in exceptional circumstances. A change in
these parameters may only occur after consultation with
DÜRKOPP ADLER.