6.7 Changing Needles

Loosen screw 1 and remove the needle.
Push the new needle up to the stop into the drilled hole in the needle bar 4.
Tighten screw 1.
Not observing the above correction can lead to the following errors:
Change to a thinner needle:
Change to a thicker needle:
1
2
3
Caution Risk of Injury !
Turn the main switch off.
Change the needle only with the sewing machine turned off.
ATTENTION !
The furrow 2 must face the hook point 3 (see sketch).
ATTENTION !
After a change to a different needle thickness, the
clearance of the hook to the needle must be corrected (see
Service Instructions).
- Missing stitches
- Damage to the thread
- Damage to the hook point
- Damage to the needle
4