CHIMNEY CAP : a device placed on the top of the flue to facilitate the dispersion of fumes into the atmosphere.
CHIMNEY CAP technical requirements : it must have a section equivalent to that of the flue;
- it must have a useful section not less than double the internal section of the flue;
- it must prevent the entry of rain and foreign bodies and ensure the discharge of fumes in any
atmospheric condition;
- it must ensure an adequate dilution of fumes and be positioned outside the backflow area;
- it must be without mechanical means of suction.
The
direct
( even open air ).
2.5 Brazier and baffle position check
Before lighting the stove make sure the brazier is in the correct position, i.e. fitted in the special slots. Also make
sure the top smoke baffle is properly fitted. A wrongly positioned baffle can result in malfunctioning and excessive
blackening of the glass.
At every stove lighting, check the correct position of the brazier on the brazier holder.

2.6 Electrical connection

Connect the end of the power cable to the wall socket.
The voltage supplied by the system must match that specified on the stove dataplate and in the technical data
section of this manual. Plug the device power cord must be connected only AFTER the end of the installation and
assembly of the device and must remain accessible.
During stove idle periods it is advisable to remove the power cable (wiring diagram fig. 3)
- Make sure the electrical system is equipped with an earth and differential switch in accordance with the
current Regulations.
- The power cable must never touch the stove exhaust pipe.
2.7 Wiring diagram for zone system
Before installing the heating stove in the house, check the type of heating system;
in case of several zones, a special electronic controller for multi-zone circuits, available as an optional, must be
installed. This is to prevent overheating of the heating chamber due to possible simultaneous closing of the zone
valves and consequent stopping of hot water flow.

2.8 Plumbing connections

The heating capacity of the unit must be previously established by calculating the building's heat requirement
according to current regulations, by contacting a specialised technician.
According to Italian Standard UNI 10412-2 (2009) and proper installation technique, a heating system must be
provided with all the adjustment, control and safety components to ensure proper and safe operation, as well as
shutoff and non-return valves to allow the boiler to be isolated from the system in case of maintenance and/or
checks. Before connecting the boiler to the water circuit, thoroughly clean all system pipes to remove any residuals
or machining residuals that could compromise the proper operation of the adjustment, control and safety
components. Proceed slowly during heating chamber water filling, to allow correct and complete evacuation of the
air from the vent ( for a closed vessel system from 1.1 to 1.5 bar ). The pellet stove has an internal heating circuit
complete with circulating pump, safety valves, air vent, temperature probes, open vessel and pressure transducer.
If the heating system is managed in zones a multi-zone controller, available on request, must be installed.
To display the boiler's water circuit pressure, just press the control panel button P5 for 3 seconds.
During stove transport the gaskets in the plumbing system may come loose and/or break, causing water leaks during
normal operation; therefore make sure to check the tightness of the circulating pump and heating chamber
connection rings and vent the residual air during water filling and after the first hours of operation.
To connect the stove to a heating system it is advisable to contact a competent technician in order to best optimise
the plumbing connections and the performance of the entire system without compromising stove operation
(hydraulic diagram fig. 4).
2.9 Emergency
Suitable fire-prevention devices should be arranged for any eventuality. In case of a fire, proceed as follows:
- Immediately disconnect the plug.
- Extinguish the fire using suitable fire-extinguishers.
- Call the fire department immediately.
- Do not use jets of waters to extinguish the fire.
discharge
of
fumes
must
take
place on
the
roof
45
and
not
towards
closed