Programming

System Programming

Prompting the WE-6 allows:
Displaying sump temperature in Centigrade or
G
Fahrenheit.
Recognizing and controlling one or two
G
independent drains. (Two independent drains will
apply only for special applications.)
Enabling or disabling the Advance key in the Run
G
Mode.
Enabling or disabling the Manual Mode.
G
Enabling or disabling wet clean functions (affects
G
Auxiliary 1 and 2 outputs).
Selecting balance routine (active if inverter
G
balance detection is utilized).
Reading or resetting the cycle count.
G
To prompt the computer:
1. Locate the key-operated programming switch:
On 135-pound models, the Program Mode
G
switch is located behind an access door
directly below the emergency stop button (top
right on the front panel of the washer-
extractor).
On 250-pound models, the Program Mode
G
switch is located on the back side of the
computer access door (left side of front panel
of the washer-extractor) below the computer
board.
Insert the key and turn the switch to the
PROGRAM position. The display will read
"CYC00".
42
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
2. Press the Auxiliary key, key 2, and key 9 in that
order. The display will read either "CEN"
(Centigrade) or "FAR" (Fahrenheit). To choose
the alternate feature, press key 0.
3. Press the Enter key. The display will read either
"1DRAIN" or "2DRAIN". The normal prompt
for most applications is "1DRAIN". "2DRAIN"
is used only for special applications. Consult
factory for full details. To choose the alternate
feature, press key 0.
4. Press the Enter key. The display will read either
"ADV" or "NO-ADV". The prompt "NO-ADV"
will disable the Advance key in the Run Mode,
thereby preventing the operator from advancing
the computer through steps of the cycle before
they are complete; also it will not be possible to
advance to any step before starting a cycle if
"NO-ADV" is selected. To choose the alternate
feature, press key 0.
5. Press the Enter key. The display will read either
"MANUAL" or "NO-MAN". If "MANUAL" is
displayed, the Manual Mode will be enabled
during normal operation. If "NO-MAN" is
displayed, the Manual Mode will be disabled
when a cycle is run, even if the Manual operation
key sequence is entered. To choose the alternate
feature, press key 0.
6. Press the Enter key. The display will read either
"WET CL" or "NO WCL". To choose the
alternate feature, press key 0. If "WET CL" is
displayed, wet clean functions are enabled. If
"NO WCL" is displayed, wet clean functions are
disabled.
F232101