Operation
Wet Clean Functions
Wet clean functions include a reduced wash speed
capability and a recirculation pump capability. These
functions are enabled by the WET CL / NO WCL
prompt selection. Other wet clean features are
permanently enabled, and can be used for other
applications as well. In particular, extra supply
capability (up to eight supplies, in two banks of four
supplies), and additional agitation actions as outlined
below.
Agitations:
wash 1 - normal: 18 seconds forward / three
G
seconds off / 18 seconds reverse / three seconds
off; repeat
wash 2 - gentle: three seconds forward / 27
G
seconds off / three seconds reverse / 27 seconds
off; repeat
wash 3 - no rotation
G
wash 4 - ten seconds forward / 20 seconds off /
G
ten seconds reverse / 20 seconds off; repeat
wash 5 - uses most recent agitation; defaults to
G
wash 1 agitation
wash 6 - super gentle: four seconds forward / 56
G
seconds off / four seconds reverse / 56 seconds
off; repeat
wash 7 - no rotation; drain 1 (sewer drain) open;
G
no attempt to refill to level
Using the auxiliary 1 (A1) and auxiliary 2 (A2)
outputs for wet cleaning
The A1 and A2 outputs (so labeled on the solid state
WE6 output PC board) can be made to operate as
timed outputs, or to remain on until a drain step.
18
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
Reduced wash speed
Normally, the A1 output would govern optional
reduced wash speed. This means that if the WE6 is
prompted for "WET CL", and then an auxiliary 1 "A1"
step is programmed for any amount of time (one
second is a good choice for time in the event of
controlling reduced wash speed), the A1 output will
remain on until a drain step, or until stop routine.
Thereby the reduced wash speed remains in effect as
long as A1 remains on.
For example, with "WET CL" prompt selected, a wash
1 agitation is wanted, but at reduced wash speed.
Program auxiliary 1 step for one second, then program
a wash 1 step. The A1 output will remain on during the
wash 1 step, selecting reduced wash speed during the
wash 1 step. Upon reaching a drain step, or upon
entering the STOP routine, the WE6 will operate the
machine at reduced wash speed (PROVIDED the
machine is equipped with the necessary hardware for
controlling reduced wash speed).
Control of an optional recirculation pump
The A2 output will also remain on until a drain or the
STOP routine if the WE6 prompt is "WET CL" and if
"1DRAIN" is selected. This would allow control of an
optional recirculation pump by permitting the pump to
continue operating during a wash step. For this
control, program an auxiliary 2 "A2" step for one
second or other suitable time, and the output would
remain on until a drain step or until the STOP routine.
The auxiliary 2 step would also go off upon entering a
Wash 7 step.
Note that "2DRAIN" prompt will OVERRIDE wet
clean control of auxiliary 2 output. If "2DRAIN" is
selected that means that the auxillary2 output is
reserved for controlling a second independent drain
(not for integrated reuse - you should select
"1DRAIN" for integrated reuse). Also, if "2DRAIN"
is selected. the WE6 will not permit programming and
auxiliary 2 step.
F232101

Capítulos

Tabla de contenido
loading

Este manual también es adecuado para:

Sf250pvSf250pv tiltF135pvUf250pvUf250pv tilt

Tabla de contenido