Unit Configuration; Installation And Connection - Oase AquaMaxEco Expert 20000/12 V Instrucciones De Uso

Ocultar thumbs Ver también para AquaMaxEco Expert 20000/12 V:
Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 43

Unit configuration

 B
AquaMax Eco Expert 20000 / 27000 / 12 V
1
Pump casing
• The position of the outlet can be changed by fitting the pump casing rotated through 90°.
2
Inlet (suction socket)
3
Filter basket
• Filters coarse dirt and leaves when installed in a submersed position.
4
Outlet (pressure socket)
5
Stand
• Ensures secure and stable positioning of the pump.
• Can be firmly bolted to the ground.
6
Switch for switching on/off the SFC-function (Seasonal Flow Control)
7
Connection line, plug connector
8
Switching power pack
• Pump power supply
EGC
EGC connection
IN/OUT
− Connection for Eco Control or for integration into an EGC-network (optional).
Important: Moisture at the connections can damage the pump.
− Only remove the protection caps for connecting the Connection Cable EGC lines or terminal resistor.
− Ensure that the rubber seals are clean and fit exactly.
− Replace damaged rubber seals.

Installation and connection

The pump is either installed submersed (in water) or dry (outside the water). The switching power pack is only suitable
for dry installation.
The use of the pump is only permitted with observance of the specified water quality. (→ Water quality)
• Pool water or salt water can impair the appearance of the unit. Such impairments are excluded from the guarantee.
N O T E
The pump will be destroyed, if water penetrates the plug connectors of the connection line.
• Do not undo the union nuts on the plug connectors.
N O T E
If the pump is used for conveying excessively soiled water, the impeller unit will be subject to increased wear
and will require earlier replacement.
• Thoroughly clean the pond or pool before installing the pump.
• Install the pump approx. 200 mm above the ground of the pond to prevent excessively soiled water from
being drawn into the pump.
Submerged installation of the pump
Adhere to the following conditions for dry installation:
 C
• Ensure that the switching power pack is installed at least 2 m from the pond.
• Ensure that the plug connection of the connection line is not in the water.
• Only operate the pump when it is below the water surface level.
• Only operate the pump with the filter basket installed.
• Ensure that the pump is in a secure and stable position.
• The position of the pump outlet can be changed. The pump casing has to be turned to achieve a different position.
(→ Turning the pump casing to achieve a different position )
- EN -
19
Tabla de contenido
loading

Este manual también es adecuado para:

Aquamaxeco expert 27000/12 v