Self-Learning Of Working Times - V2 CITY4-EVO Manual De Instrucciones

Ocultar thumbs Ver también para CITY4-EVO:
Tabla de contenido
Idiomas disponibles

Idiomas disponibles

12 - SELF-LEARNING OF WORKING
TIMES
This menu allows the automatic learning of the times necessary to
open and close the gate. The encoder positions are also saved, if
enabled.
m
ATTENTION: before starting the procedure, it is
necessary to check the following points:
• Limit switches and encoder: these devices, if installed, must be
enabled through the special menu (
• ADI Interface disabled (DEFAULT): the ADI interface must be
i.Adi
disabled through the
• STANDARD (DEFAULT) operation mode: the
StAn
must be set on
m
WARNING: if the function PHOTOCELL SHADOW
ZONE is active, the intervention of the photocell during
the self-learning does not open the gate; the control unit
automatically sets the parametersof the shadow zone in
order to disable the photocell when the gate passes in the
position of its intervention.
Position the door at half stroke and proceed with the following
points:
1. Press and hold down the MENU key until the
on the display
2. Release the MENU key: the display will show
MENU key only if you want to leave this menu)
t.LAv
3. Press the DOWN key:
4. Press the MENU key to start the self-learning cycle for the work
cycle times.
FC.En
Enco
,
).
menu.
Strt
parameter
-APP
appears
ESC
(press the
will appear on the display
LIMIT SWITCHES OR SENSOR OF OBSTACLES IS ENABLED
1. The door is closed until the limit
switches comes into action, or
the sensor of obstacles detects
that the door is locked
2. An opening manoeuvre is
carried out, the operation ends
when the limit switches comes
into action, or the sensor of
obstacles detects that the door
is locked
3. A closing manoeuvre is carried
out, the operation ends when
the limit switches comes
into action, or the sensor of
obstacles detects that the door
is locked
4. The detected parameters are stored and the unit is ready for
use
NO LIMIT SWITCHES AND SENSOR OF OBSTACLES IS
DISABLED
ATTENTION: in this case the limits of the run must be signalled
with a START order
1. The door is closed until the unit
receives a START order
2. An opening manoeuvre is
carried out, the operation ends
when the unit receives a START
order
3. A closing manoeuvre is carried
out, the operation ends when
the unit receives a START order
4. The detected parameters are stored and the unit is ready for
use
- 41 -
Tabla de contenido
loading

Tabla de contenido