Error And Warning Codes 6 - DENTSPLY DeguDent Degutron eco Manual De Instrucciones

Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

Error/
Description
Warning
E012
Water pressure low
E021
Over temperature
power unit
E030
IZK Peak current too
large
E040
Generator switched
on/off too often
E050
Over temperature
generator
E051
Power on time too long • Too many casts per hour
E055
No vacuum
E064
Power on time too long • Too many casts per hour
E065
Generator power too
low
E066
Generator power too
high
E081
Casting chamber
pressure out of
tolerance
Cause
• Tubes too long
• Pressure to low
• Dirt
• Unit can not cool down
• To many consecutive casts
• Water cooling insufficient
• Not enough material in the crucible
• Old crucible
• No crucible inserted
• Max. 5 switches/min
• Unit can not cool down
• To many consecutive casts
• Water cooling insufficient
• Lit not closed and locked
• No vacuum connected or dysfunctional
• Lit lock not tight
• More than 15 % deviation
• More than 15 % deviation
• Lit not locked
• No sufficient pressure supply
• No vacuum supply
• Lit lock not tight

Error and Warning Codes 6

Action
• Keep the connections as short as possible
• Water pressure should be 2.5–5.0 bar with
min. flow of 1.5 l/min
• Clean circuit and exchange tubes
• Do not block the space at the back of the
machine
• Not more than 6 casts/hour
• See E012
• Only heat with inserted filled crucible
• Switch off the casting unit and avoid to
many switching events
• Do not block the space at the back of the
machine
• Not more than 6 casts/hour
• See E012
• Not more than 6 casts/hour
• Close and lock lit
• Control lit ring for damages or dirt
• Check vacuum pump and connections
• Tighten lit lock
• Not more than 6 casts/hour
• Check electric power supply
• Check electric power supply
• Close and lock lit
• Control lit ring for damages or dirt
• Check pressure supply (4–6 bar)
• Check vacuum pump and connections
• Tighten lit lock