Installation Instructions; Information About Gas Fryer Optima Series; Laws, Regulations And Technical Directives To Be Complied With; Installation Place - Diamond OPTIMA Serie Manual De Instrucciones

Ocultar thumbs Ver también para OPTIMA Serie:
Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

2.
Installation must be performed by qualified technicians according to the law in force.
See technical date tables II.
WARNINGS:
Should the unit be installed against a wall, the latter must be heat-resistant to temperatures of 80°C and must be fireproof, or
it has to be placed at a distance of 10 cm.
Before proceeding with the installation, remove the protective plastic film from the relevant parts, eliminating any adhesive
residues with an appropriate cleaning product suitable for stainless steel.
Install the unit in a horizontal position; its correct levelling will be achieved by rotating the adjustable feet.
If the unit is installed by itself, it is advisable to fasten it to make its stability safer: especially for models G77/F2V7-A4S,
G77/F2V7-A4B and G77/F14-A4S, G77/F14-A4B.
2.1

INFORMATION ABOUT GAS FRYER OPTIMA SERIES

This manual applies to our Gas Fryers OPTIMA Series, Type A
See tables II.
The label according to EN437 and EN203-1-2 regulations, is located:
a) inner door side
Example for Italy label:
Category II 2H3÷
Pe = Incoming Pressure
Pi = Nozzle Pressure
2.2

LAWS, REGULATIONS AND TECHNICAL DIRECTIVES TO BE COMPLIED WITH

The following indications should be observed during installation:
- Accident and fire regulations in force
- Prescriptions by the Gas Supply Company, which should issue an authorisation before installation.
- Instructions for the "Installation of gas equipment"
- Hygienic regulations.
2.3

INSTALLATION PLACE

- The unit should be installed in adequately ventilated places. (This unit requires a draft of at least 2 cu.m/hr x kW P.T.
(Thermal capacity).
- Install the equipment in compliance with the safety rules applicable in the country where the equipment is installed.
2.4

POSITIONING

- The various units may be installed individually or together with other units of our range.
- This unit is not suitable for encasing.
- The distance between side walls must be a minimum of 10cm; should the distance be less or the wall or floor material be
flammable, it is essential to use a thermal insulator.

INSTALLATION INSTRUCTIONS

Category II (Natural Gas and L.P.G.).
1
20,37,50
- 21 -
K
GB
Tabla de contenido
loading

Este manual también es adecuado para:

G77/f2v7a4-nhG77/f2v7-a4sG77/f14-a4sG77/f28-a7sB-gf4772vb

Tabla de contenido