Replacing The Left / Right Slide Potentiometer - NAMCO GUNMEN WARS Manual Del Operador

Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 10

8-8 Replacing the Left / Right Slide Potentiometer

1.
Remove the Gun Vac-Forms.
2.
Remove the gun Frame.
3.
Remove the slide covers (S), (R) and (L).
5.
Disconnect the potentiometer connector.
Double-point (M4 × 6)
6.
Loosen the double point screw (M4x6) and remove the actuator arm.
7.
Replace the potentiometer.
Note:
When replacing the potentiometer ensure that the double point screw
(M4x6) engages on the flat of the potentiometer shaft, and that the
correct colour wires are connected to the correct terminals.
8.
Reasemble in reverse order.
NOTE:
After replacing the potentiometer REINITIALIZE the game.