NAMCO GUNMEN WARS Manual Del Operador página 69

Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 10
5.
Disconnect the potentiometer connector.
Actuator Arm
6.
Loosen the double point screw (M4x6) and remove the actuator arm.
7.
Replace the potentiometer.
Note:
When replacing the potentiometer ensure that the double point screw
(M4x6) engages on the flat of the potentiometer shaft, and that the
correct colour wires are connected to the correct terminals.
Whi/Red
8.
Reasemble in reverse order.
NOTE:
After replacing the potentiometer REINITIALIZE the game.
(see section 7 page 5 6
Connector
2
Whi/Blk
Whi/Vio
).
Page 69
Double-point (M4 × 6)