Problem
Possible cause
Current sensors not or incorrectly configured
EEBus connection was unsuccessful or con-
nection was briefly interrupted
EEBus device has the wrong phase assign-
ment
A fuse that does not protect the energy man-
ager has tripped
The vehicle is not charged with
Current sensors are connected the wrong way
the available excess solar elec-
round
tricity
Current sensors not or incorrectly configured
EEBus connection was unsuccessful or con-
nection was briefly interrupted
Remedy
e
Check whether the connection positions of the current sensors on the
energy manager match the configuration in the Web Application Home
installation (CT#). In addition, check that the configured phases of the
current sensors match the voltage measurement phases.
e
Repeat EEBus connection on the EEBus device and, if necessary, boost the
communication signal (WiFi or PLC).
g Pay attention to the EEBus device manual
.
e
In the Web Application HOME INSTALLATION, check whether the (correct)
current sensors were assigned to the current consumers.
You can purchase current sensors for protecting further fuses for cables lead-
ing to the EEBus device from your Porsche partner.
e
Have these fitted and configured by a qualified electrician.
e
The qualified electrician checks whether the direction arrow of the current
sensor is pointing towards consumption, and whether the cables are cor-
rectly connected to J200, J300 and J301 connectors.
e
Check whether the connection positions of the current sensors on the
energy manager match the configuration in the Web Application Home
installation (CT#). In addition, check that the configured phases of the
current sensors match the voltage measurement phases.
e
Repeat EEBus connection on the EEBus device and, if necessary, boost the
communication signal (WiFi or PLC).
g Pay attention to the EEBus device manual
.
Set up
47