Installation and connection
Con-
Pi
Signal
nec-
n
tor
J900
1
RS485 signal B -
/
2
RS485 signal A +
J901
3
Earth
4
Earth
5
CAN Low
6
CAN High

Connection to the power grid

Installing circuit breakers
Information
Line protection fuses are not included in the scope
of supply and must be installed by a qualified electri-
cian.
The energy manager has no internal fuses. The volt-
age measurement, external power supply and relay
inputs must therefore be fitted with suitable backup
fuses.
Use of the energy manager requires overcurrent
protection for all supply leads. Make sure you se-
lect fuses with a sensitive trigger characteristic.
Fuses are selected based on what components
are available in the country of use.
Use components with the lowest trip current and
shortest trip time.
40
Preparing the distribution cabinet
For information on the required space for the energy
manager:
g Refer to chapter "Technical Data" on page 49.
e
To install the energy manager inside the distri-
bution cabinet, allow a horizontal pitch (HP) of
11.5 on a DIN rail.
e
Install the mains power supply unit of the energy
manager at a minimum distance of 0.5 HP from
its housing.
e
Protect all electrical interfaces from direct/indi-
rect contact.
Fig. 25 Preparing the distribution cabinet
Horizontal pitch 11.5
A
Horizontal pitch 9
B
Horizontal pitch 0.5
C
Horizontal pitch 2
D
Installation in the distribution cabinet
b All cables are connected to the energy manager.
b The DIN rail bracket on the housing of the energy
manager has been released.
1. Position the DIN rail bracket at an angle against
the DIN rail in the distribution cabinet.
2. Tilt the housing of the energy manager and lay
evenly on the DIN rail.
3. Fasten the DIN rail bracket to the housing of the
energy manager.
Fig. 26 Installation in the distribution cabinet
4. Check that the energy manager is securely en-
gaged on the DIN rail.
Installing the current sensors
NOTICE
Sensor with incorrect direction of measurement
loading