Installation and connection
Overview of connectors
The overview of device connections ((Fig. 18),
(Fig. 19)) shows the connection position of connec-
tors used for current sensors, voltage sensors, relay
contacts and communication. The diagram illustrates
the position of the pins for each type of connec-
tor. The tables show the pin assignment with corre-
sponding signal.
g Refer to chapter "Overview of device connections"
on page 36.
Connectors for current measurement
Information
It is essential to note the connection positions of
the current sensors, the type of current sensor, their
phase assignment and the rated current of the phase
fuse, as you will be asked for this information later on
when configuring the energy manager (home installa-
tion).
Parameter
Value
Connector
J200/J300/J301
Manufacturer
Phoenix contact
Socket part number
1786853
Connector part number
1790124
Overview of J200/J300/J301 connectors
The connectors of the current sensors (J200, J300,
J301) are identical and can be connected to any of
the connections provided ((Fig. 18
2/3/4
Fig. 20 Overview of J200/J300/J301
Pin 1
1
Pin 2
2
Con-
Pin
Signal
nector
J200
1
Current sensor 1 ("l", black)
2
Current sensor 1 ("k", white)
3
Current sensor 2 ("l", black)
4
Current sensor 2 ("k", white)
5
Current sensor 3 ("l", black)
Installation and connection
Con-
Pin
Signal
nector
6
Current sensor 3 ("k", white)
))
7
Current sensor 4 ("l", black)
8
Current sensor 4 ("k", white)
J300
1
Current sensor 5 ("l", black)
2
Current sensor 5 ("k", white)
3
Current sensor 6 ("l", black)
4
Current sensor 6 ("k", white)
5
Current sensor 7 ("l", black)
6
Current sensor 7 ("k", white)
7
Current sensor 8 ("l", black)
8
Current sensor 8 ("k", white)
J301
1
Current sensor 9 ("l", black)
2
Current sensor 9 ("k", white)
3
Current sensor 10 ("l", black)
4
Current sensor 10 ("k", white)
5
Current sensor 11 ("l", black)
6
Current sensor 11 ("k", white)
7
Current sensor 12 ("l", black)