Pages 2-3: Factory Settings
Figure 56: Factory Settings
These pages are used for setting parameters that are specific to the
compressor. All of the factory settings that are adjustable are listed below.
All settings on these pages are password protected.
•
Rated Pressure (psi – 100, 115, 15, 190)
•
Enable Two Stage (On/Off )
•
Starter Type (Star-delta, Remote Starter, Soft Starter)
•
Service Level (0, 1, or 2)
•
Service Time Period (1000 – 8000, in increments of 1000 hours)
•
Enable Modulation (On/Off )
•
Enable PAC (On/Off )
•
Enable Dryer (On/Off )
•
Running Hours (adjustable)
•
Loaded Hours (adjustable)
•
VSD Blower (On/Off )
•
Enable Low Ambient (On/Off )
Pages 4-5: Factory Settings
Figure 57: Factory Settings
These pages are used for displaying software information for the controller.
All items are read only.
80446339 Rev C
All manuals and user guides at all-guides.com
Folder Options (Variable Speed)
Page 1: System Overview
This is the factory default display after powering up the system.
Target Pressure Setpoint is indicated in the white box and by the white
•
arrow, which is always centered on the gauge. This is the pressure that
the compressor is trying to maintain.
Automatic Stop Setpoint is indicated in the white box and by the
•
white arrow, which is always right of center on the gauge. When the
compressor reaches this setpoint the compressor will unload and stop.
•
Package Discharge Pressure is indicated by the large numbers centered
below the gauge and by the red arrow. This is the output pressure of the
compressor.
•
Pressure Unit of Measure is indicated below the Package Discharge
Pressure. This is selectable from the GENERAL SETTINGS folder.
Percent Capacity is indicated on the lower left side of the screen in
•
numeric and bar graph form. This is how much air the compressor is
producing as a percentage of its maximum capacity.
Airend Discharge Temperature is indicated by the numbers in the lower
•
right of the display.
•
Temperature Unit of Measure is indicated to the right of the Airend
Discharge Temperature. This is selectable from the GENERAL SETTINGS
folder.
•
Run Hours indicate the number of hours the compressor has been
running.
The target pressure and automatic stop set points can be selected and
modified on this page . All other information on this page is read only .
Home folder
Figure 58: Systems Overview
NOTICE
EN-0