Ferroli ATLAS D ECO 34 COND SI UNIT Instrucciones De Uso, Instalación Y Mantenimiento página 36

Ocultar thumbs Ver también para ATLAS D ECO 34 COND SI UNIT:
Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 18
When the boiler is turned off, the PCB is still powered.
Domestic hot water and heating are disabled. The antifreeze system remains activated.
To relight the boiler, press the on/off button (detail 9 fig. 1- ) again for 1 second.
The boiler will be immediately ready to operate whenever domestic hot water is drawn
or in case of a room thermostat demand.
2.4 Adjustments
Summer/Winter Switchover
Press the Summer/Winter button (detail 6 - fig. 1) for 1 second.
The display activates the Summer symbol (detail 27 - fig. 1): the boiler will only deliver
domestic hot water. The antifreeze system remains activated.
To deactivate Summer mode, press the Summer/Winter button (detail 6 - fig. 1) again
for 1 second.
Heating temperature adjustment
Use the heating buttons (details 3 and 4 - fig. 1) to vary the temperature between a min-
imum of 30°C to a maximum of 80°C.
It is advisable not to operate the boiler below 45°C.
DHW temperature adjustment
Use the DHW buttons (details 1 and 2 - fig. 1) to adjust the temperature from a min. of
50°C to a max. of 75°C.
Room temperature adjustment (with optional room thermostat)
Using the room thermostat, set the temperature desired in the rooms. If the room ther-
mostat is not installed the boiler will keep the heating system at its setpoint temperature.
Room temperature adjustment (with optional remote timer control)
Using the remote timer control, set the temperature desired in the rooms. The boiler unit
will set the system water according to the required room temperature. For information on
the remote timer control, please refer to its user's manual.
ECO/COMFORT selection
The unit has a function that ensures a high domestic hot water delivery speed and max-
imum comfort for the user. When the device is activated (COMFORT mode), the water
contained in the boiler is kept hot, therefore ensuring immediate availability of hot water
on opening the tap, without waiting times.
The device can be deactivated by the user (ECO mode) by pressing the eco/comfort
button (detail 7 - fig. 1). To activate the COMFORT mode, press the eco/comfort button
(detail 7 - fig. 1) again.
34
EN
fig. 8
fig. 9
fig. 10
fig. 11
cod. 3541Q474 - Rev. 00 - 12/2021
ATLAS D ECO 34 COND SI UNIT
Sliding temperature
When the optional external probe is installed the control panel display (detail 5 - fig. 1)
shows the actual outside temperature read by the probe. The boiler control system op-
erates with "Sliding Temperature". In this mode, the temperature of the heating system
is adjusted according the outside weather conditions, in order to ensure high comfort and
energy saving throughout the year. In particular, as the outside temperature increases,
the system delivery temperature is decreased according to a specific "compensation
curve".
With Sliding Temperature adjustment, the temperature set with the heating buttons -/+
(details 3 and 4 - fig. 1) becomes the maximum system delivery temperature. It is advis-
able to set a maximum value to allow system adjustment throughout its useful operating
range.
The boiler must be adjusted at the time of installation by qualified personnel. Possible
adjustments can in any case be made by the user to improve comfort.
Compensation curve and curve offset
Press the mode button (detail 10 - fig. 1) once to display the actual compensation curve
(fig. 12), which can be modified with the DHW buttons (details 1 and 2 - fig. 1).
Adjust the required curve from 1 to 10 according to the characteristic (fig. 14).
By setting the curve to 0, sliding temperature adjustment is disabled.
Press the heating buttons (details 3 and 4 - fig. 1) to access parallel curve offset
(fig. 15), modifiable with the DHW buttons (details 1 and 2 - fig. 1).
Press the mode button (detail 10 - fig. 1) again to exit parallel curve adjustment mode.
If the room temperature is lower than the required value, it is advisable to set a higher
order curve and vice versa. Proceed by increasing or decreasing in steps of one and
check the result in the room.
90
85
80
70
60
50
40
30
20
20
90
10
9
85
80
70
60
50
40
30
20
fig. 15 - Example of compensation parallel curve offset
Adjustments from Remote Timer Control
If the Remote Timer Control (optional) is connected to the boiler, the above ad-
A
justments are managed according to that given in table 1. Also, the control pan-
el display (detail 5 - fig. 1) shows the actual room temperature read by the
Remote Timer Control.
fig. 12 - Compensation curve
fig. 13 - Curve parallel offset
10
9
8
7
10
0
-10
fig. 14 - Compensation curves
90
8
10
7
85
6
80
5
70
4
60
3
50
2
40
1
30
20
6
5
4
3
2
1
-20
9
8
7
6
5
4
3
2
1
Tabla de contenido

Solución de problemas

loading

Tabla de contenido