11. Troubleshooting
Before maintenance, please check following information:
Trouble details
Control valve fail
to work
1.
Regeneration time
is incorrect
2.
3.
Leakage
Noise
1.
High hardness
2.
of outlet water
3.
Brine failure or
brine deficient
Brine tank water
1.
overflow
2.
No soft water after
regeneration
Too big or too small
flow rate of backwash
All manuals and user guides at all-guides.com
Cause
Power plug isn't plugged in.
3.
Socket breakdown.
4.
Power outage.
5.
Transformer damaged.
6.
Time of day doesn't set
correctly.
Power failure more than 3 days.
Bad contact.
Connector loose.
1.
O-ring broken.
2.
Air in the device.
Not good quality of raw water.
Too long time of regeneration
period
Bypass is open.
Low inlet pressure.
1.
Brine pipe hindered.
2.
Injector broken.
3.
Brine pipe air leakage.
4.
Too long time of brine refill.
Too much water left after brine.
Valve broken.
1.
Low inlet pressure.
2.
No salt in brine tank.
3.
Injector hindered.
4.
Riser pipe o-ring broken.
5.
Without flow restrictor.
1.
Foreign material in flow
2.
restrictor.
Solution
Connect to power.
1.
Repair or replace socket.
2.
Check the circuit and power supply.
3.
Replace the transformer.
4.
Reset the clock
Screw tight connector or reconnect.
1.
Replace O-ring.
2.
Re-backwash, empty air.
Contact with supplier.
1.
Shorten regeneration cycle time.
2.
Close bypass
3.
Increase inlet pressure, more tan 1,5
1.
bar.
Check and eliminate the blockage.
2.
Replace injector.
3.
Check brine pipe components,
4.
eliminate leakage.
Shorten brine refill time.
1.
Check brine status.
2.
1.Replace the controller.
2.Increase inlet pressure.
3.Add salt and manual regenerate.
4.Disassemble injector then clean, assemble
it.
5.Replace o-ring.
Install flow restrictor.
1.
Clean foreign material.
2.
67