10. Warnings
Before reading and understanding the manual instruction, please do not operate
the device.
Forbid installing the device near heat source or take anti-heat protective measures
when install near the heat source. It is also forbidden to connect the device with the
hot-water pipeline or the pipeline with the possibility of hot-water returning.
If the raw water fails to meet the standards of local tap water, such as the sediment
concentration or residual chlorine content exceed the stand, etc., the pre-treatment
device should be installed before the device.( Such as Y type filter, ultra-filter, and so
on.)
During the operation, please check the brine tank regularly to ensure there is salt in
the tank. And when adding brine, please make sure that volume of brine should be
2/3 of the tank. When it is less than 1/3, please add in time. (Attention: make sure
the dissolving salt time is more than 6 hours so as to make the brine saturate).
-Please strictly use the salt of more than 99% purity only. Any salt with additive
or large particles is forbidden to add.
-Without being used for a long time or the pressure of the inlet water is instable,
please close the inlet port and turn off the power. Before using again, please firstly
conduct a regeneration cycle through manual operation so as to ensure the
quality of soften water.
-When use the softener for the first time or the device is idle for long period, it
is normal that the outlet water is yellow. Please put into use after 2~3 minutes
Rinsing. -Sometimes the brine in the brine tank will forms salt bridge. That is, there
is a space under the brine which prevents the salt from being dissolved and
hinders the resin regeneration. It is suggested to check regularly. If there is salt
bridge, please mash it. (As the product is constantly updating, the possibility that the
manual instruction can't accord with the product may happen. So, it is subjected to the
actual product.)