Sequence of screens in SERVICE:
∩
12:30:25
Water System
Service
Water
Remaining:
X.XXm³
State 1
Programming process of the valve. USER mode
Values
Watch
Regeneration
time
Water
hardness
After adjusting the parameters, the display shows the volume of water that can be treated.
Technical parameters setting mode (Background)
Valve programming process. TECHNICIAN mode.
52
NASSER
All manuals and user guides at all-guides.com
L1
*******************************
F69
*******************************
∩
Water System
Service
Water
Cu.F.R.:
State 2
Programming steps
When (∩) indicator in the upper left, press and
maintain (▼ ▲) for 5 seconds, until it disappears (∩)
1. Press key "validation" and enter the menu "Set Parameters"
LR1 indicates the screen as follows. The parameter "set time of day" is
It automatically selected.
2. Then press "validation" and the display shows the
LR2 screen; the value of hours "12" will blink, and by (▼ ▲)
the value of the current time in that time will be adjusted.
3. Then be pressed again "validation", and the value min
"30" blinks, and by (▼ ▲) a minute value is set.
4. Finally, press "validation" and hear a "beep" that
confirms memorization of change
1. Press and enter the menu "set parameters", as shown in
screen.
2. Press (▼) and select the "set. Regen. time" parameter;
Then click "validation" and see the LR3 screen.
The hour value "02" blinks and by (▼▲) will adjust the
Value of hours.
3. Then again press "validation" and the value minutes
"00" blinks and by (▼▲) a minute value is set.
4. Finally, press "validation" and hear a "beep" that
Confirms memorization of change.
1.Pulsar "validation" and enter "Set parameters" menu,
as shown in Figure LR1.
2. Press the (▼) 2 times and select the "Set Water
Hardness"; then press "validation" and LR4 screens appears.
The hardness value "150" will blink, and by (▼▲) is introduced
The hardness value measured at the entrance.
3. Finally, press "validation" and hear a "beep" that confirms
the memorization of changes.
-
CEASA
∩
12:30:25
Water System
Service
Water
Regen.
X.XXm³/h
Time:
State 3
12:30:25
2:00
Screen
LR1
Set Parameters
> Set Time of Day
Set Regen. Time
Set Water Hardness
LR2
Set Time of Day
12:30
LR3
Set Regen. Time
02:00
LR4
Set Water Hardness
150 mg/L