A. Technical Mode Selection
During the 6 seconds the screen L1 to connect the unit to the mains appears, press "regeneration + down" key
to simultaneously and hold for about 3 seconds to enter Menu Technical L2 (Background).
L1
*******************************
F69
*******************************
B. Adjust Parameters
Under the Technician mode (L2), you can adjust the following parameters. Operation mode (Filtration/Softening),
Valve model, control type, flow uni t, volume of resins, i nterval of regener ation days , backw ash time, Brine and s
how resin time, brine and fast rinse time.
Values
Set Mode
Set Valve
Model
Set Type
All manuals and user guides at all-guides.com
►►►►►►
Programming steps
Under the Technician mode (L2)
1. Select "Set Mode" parameter by (▼▲)
2. Press "validation" and select Filter or Softener (LT1)
3. Press "validation" to return to the Technician mode (L2)
Under the Technician model (L2)
1. Select "Set Valve Model" parameter by (▼▲)
2. Press "validation" and select F63/65/68/69/82/79 (LT2)
3. Press "validation" to return to the Technician mode (L2)
Under the Technician model (L2)
1. Select "Set Type" parameter by (▼▲)
2. Press "validation" and select Time clock Type or Meter Type (LT3)
3. Press "validation" to return to the Technician mode (L2)
›› Set Mode
Set Valve Model
Set Type
Set Flow Rate Unit
53
NASSER
Screen
LT1
Set Mode
○ Filter
● Softener
LT2
Set Valve Model
○ F63
○ F65
○ F68
● F69
LT3
Set Type
○ Time clock Type
● Meter Type
-