Setting the third cycle (Brine refill)
Press DOWN for adjusting the third cycle. The indicator light will mark the program 4, which corresponds to the
time of "Brine refill".
Using the "Validation" button, and with the help of the UP and DOWN keys select the loading time of brine refill.
Annex
II).
(According to the
Press "Validation" to confirm.
Adjusting the fourth cycle (Fast rinse)
Press DOWN for adjusting the fourth cycle. The indicator light will mark the program 5, which corresponds to the
minutes of "Fast rinse".
Using the "Validation" button, and with the help of the UP and DOWN keys dial the fast ri nse. (According to the
Annex
II).
Press "Validation" to confirm.
Days between regenerations H-
We press the DOWN key and appears H- (days between regenerations)
These are days that will be a regeneration of maintenance in case of no water consumption after the days we have
programmed.
Using the "Validation" button, and with the help of the UP and DOWN keys select the days you want, from 00 to 40.
The default is always 30 days.
Press "Validation" to confirm.
External signal mode
Finally, when you press the key DOWN, we appear b-01 (mode external signal)
This position has two varieties:
b-01 - To exit programming auxiliary pump / solenoid additional connection during washing.
Useful in installations with insufficient pressure or external bypass controller (requires additional hardware)
b-02 - For programming additional auxiliary output for solenoid connection depressurization during the
repositioning of the ceramic disk.
Useful in large and high pressure equipment. It requires additional items.
Using the "Validation" button, and with the help of the UP and DOWN keys select the desired option by default is
always in b-01. Press "Validation" to confirm.
To complete the process again just press the DOWN key.
The current time. Press "Regeneration" key to exit the program and return to the screen of Service
58