It can be changed by pressing the "Validation" key, then adjust with the UP and DOWN keys, the desired value.
Press "Validation" to confirm.
Setting the time of regeneration
Press the DOWN key, so that when regeneration appears.
Change the time by pressing the "Validation" key, then adjust with the UP and DOWN keys.
Normally you will leave at 2:00 am, which is the time that is preset..
Press "Validation" to confirm.
Settings Interval backwash times F-00
Press the DOWN key. Program 1 appears, which corresponds to the "interval backwash times", the number of
regenerations until the valve make a backwash will appear on the screen. To upflow valves is not necessary to
perform a backwash in each regeneration, so this setting allows you to specify how many regenerations each
make a backwash. To adjust, press "Validation" and change with the UP / DOWN buttons until the desired
value. Press "Validation" to confirm.
F - 00 is a backwash every time you make a regeneration.
F - 01 is a backwash every 2 regenerations.
F - 02 is a backwash every 3 feedbacks. And so on.
Settings Volume to be treated
Volume setting for water to be treated M3, gallons or liters (options A-01, A-02)
Where we can see the cubic meters, gallons or liters of water to be treated. We will mark the volume that can
softening, according to the table.
↓Mod
20ºF ↓
16 lts
4,0 m³
25 lts
6,25m³
38 lts
9,50 m³
Press the "Validation" key and the value starts to flash.
You can change this number using the UP and DOWN buttons. Program the appropriate amount according to
the amount (liters) of resin and water hardness. Finally confirm with the "Validation" key.
60
NASSER
-
All manuals and user guides at all-guides.com
Water Hardness in ºF
30ºF ↓
40ºF ↓
50ºF ↓
2,67 m³
2,0 m³
1,60m³
4,17 m³
3,13 m³
2,50 m³
6,33 m³
4,75 m³
3,80 m³
CEASA
60ºF ↓
70ºF ↓
85ºF ↓
1,33 m³
1,14 m³
0,94 m³
2,08 m³
1,79 m³
1,47 m³
3,17 m³
2,71 m³
2,24 m³
100ºF ↓
0,80 m³
1,25 m³
1,90 m³