8.3.2 Display equipment with LED´s
All valves are shipped with a standard configuration. However, this schedule can be adjusted according to the
needs and quality of water in the area where the equipment is installed.
Menu/Validation
Unlock and Access programming
To unlock and enter the manual mode and program changes. Press the UP and DOWN keys simultaneously until the
key icon disappears and the icon of the tool (programming mode) appears.
Setting the valve clock
Press the "Validation" twice, and using the UP and DOWN buttons set the clock dial in real time of day key.
Press the "Validation" button to change the minutes and finally press it again to set the schedule.
Setting the type of regeneration
Press the DOWN key to enter the configuration type of regeneration:
A - 01 = Delayed regeneration
A - 02 = Instant regeneration
A – 03 = Intelligent delayed regeneration
A – 04 = Intelligent instant regeneration
To change it press the "Validation" button and select the type of feedback with the UP and DOWN keys.
Confirm your choice using the "Validation" key.
Setting measurement unit: HU-
Press the DOWN key so that appears HU, reformatting capacity.
HU-01 cubic meters
HU-02 Gallons
HU-03 Liters
It can be changed by pressing the "Validation" key, then adjust with the UP and DOWN keys, the desired value.