To adjust, press "MENU / SET" and change with the UP / DOWN buttons until the desired value.
Press "MENU / SET" to confirm.
Setting for volume of water to be treated M3, gallons or liters (options A-01, A-02)
Where we can see the cubic meters, gallons or liters of water to be treated, depending on the chosen in the
"Measurement Unit Settings HU -" section value. We will mark the volume that can be descaled according to the
following table:
↓Mod
20ºF ↓
16 lts
4,0 m³
25 lts
6,25m³
38 lts
9,50 m³
Press the "MENU / SET" key and the value starts to flash.
You can change this number using the UP and DOWN buttons. Program the appropriate amount according to the
amount (liters) of resin and water hardness. Finally confirm with the "MENU / SET" key.
Regeneration: Adjustment of cycle times
The times of regeneration cycles have been pre-programmed by the manufacturer of softener. However, you can
modify the advanced programming mode as follows.
Setting the first cycle (Backwash)
From the previous state, press the DOWN key until the program 2, which is the length of backwash is displayed.
Press the "Validation" for adjusting the first cycle key. With the help of the UP and DOWN keys set the duration of
the backwash of the softener. (According to the
Press "Validation" to confirm.
Setting the second cycle (Brine and slow rinse)
Press DOWN for adjusting the second cycle. The indicator light will mark the program 3, which corresponds to the
time of "brine and slow rinse".
Press the "Validation" for adjusting the second cycle key. With the help of the UP and DOWN keys indicate time of
brine and slow rinse (According to the
Press "Validation" to confirm.
All manuals and user guides at all-guides.com
Water Hardness in ºF
30ºF ↓
40ºF ↓
50ºF ↓
2,67 m³
2,0 m³
1,60m³
4,17 m³
3,13 m³
2,50 m³
6,33 m³
4,75 m³
3,80 m³
Annex
II).
Annex
II).
60ºF ↓
70ºF ↓
85ºF ↓
1,33 m³
1,14 m³
0,94 m³
2,08 m³
1,79 m³
1,47 m³
3,17 m³
2,71 m³
2,24 m³
57
NASSER
100ºF ↓
0,80 m³
1,25 m³
1,90 m³
-