9. Start up Guide
After installing the device and setting the relevant parameter, please follow the
instructions as it's shown below:
Fill the brine tank with the planned regeneration salt and water ( refer to the below
table ), making the brine 25% saturated. Then start the device. This step is only
necesary when the device is being started for fist time.
Slowly open the inlet valve to 1/4 of its position. Avoid to open the valve too quickly
in order to not damage the device and make the resin run off. At this moment, slowly
open the network valve too.
After all air is out of pipeline, then open inlet valve completely. With a ph
meter, check the residual water hardness at the service stage. Make sure there
are no leaks in any installation part.
Notice: under normal circumstances, the user doesn't need to do any operation,
except adding a certain amount of salt into the brine tank.
All manuals and user guides at all-guides.com
Resin Tank
10 x 17
Water ( l )
10
08 x 35
10 x 35
15
23
65