4.2. From the inner chamber to get accessories and documentation. Read the appliance
certificate. Check the completeness.
4.3. Remove the product from the wooden pallet by loosening the bolts securing of the product
to the pallet.
4.4. The product may only be moved in an upright position with an anchorage that excludes any
possible impacts and movement within transport facilities.
4.5. After transporting or storing at below-freezing temperatures, the cabinet must be kept at
room temperature (at least 12 ° C) for 24 hours before connecting it to the mains.
4.6. The product should be installed no closer than 1 m from the heaters. It is forbidden use the
product:
when exposed to direct sunlight;
on a draft or on a way of air ventilating streams, including from conditioners;
in conditions of hindered air inflow to the compressor-condenser unit.
4.7. Screw in the support and use it to install the product with an inclination toward the rear wall
of 0,5 - 1 °, which amounts to a displacement of 25-30 mm from the vertical.
4.8. The internal and external surfaces of the product are covered with a protective technological
film, which must be removed before use. Then wash the surface of the product with detergent
and wipe dry.
4.9. Install brackets for shelves and shelves.
5. CONNECTION OF THE PRODUCT TO ELECTRICITY MAINS. SAFETY
PRECAUTIONS
5.1. The mains supply voltage should be 220V, frequency 50 Hz. Deviation of voltage from rated
voltage is not more than +/- 10%, frequency, not more than +/- 0,4%.
Note: If in your region the voltage drops of the mains voltage exceed these, it is recommended
that the product be connected to the network through special protective and stabilizing devices.
5.2. The product has a power cord with a grounding prong and a plug with a ground contact.
5.3. The product is connected to the mains power supply(see Fig.1) via a combined (thermal and
electromagnetic) circuit breaker with setpoint current
Fig. 1 Wiring diagram of the product to the mains
QF1 - Circuit Breaker
X1 - bipolar connector "EURO" plug-socket with grounding contact.
5.5. Before starting the product, it is necessary to ensure the integrity of the conductor insulation,
the reliability of the connections and the quality of the grounding. If any damage is found, call a
service representative.
5.6. When carrying out sanitary treatment, preventive and repair work, moving the cabinet, the
product must be disconnected from the mains by removing the plug from the outlet.
5.7. The product must be connected to a working power outlet with a grounding contact directly
(without an extension cord and adapters).
5.8. If there are signs of abnormal operation of the cabinet, a leakage of refrigerant or a violation
in the electrical part (conductor insulation failure, ground wire break, tingle when touching metal
parts, etc.) by the operating person should immediately disconnect the cabinet from the power
supply and call a service center specialist.