TATRA TPI 05 D.V Manual De Instrucciones página 206

Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 182
APPLIANCE NOT SUPPLIED WITH CABLE WITH
THREE PHASE TERMINALS
Articles supplied by us come with terminals such as in the image. To connect to the mains see
the label in the manual and stuck to the lower part of the back of the appliance near the
Information Plate .
The oven must be connected to the electricity with a rubber cable such as H07RN-F.
WARNING: the yellow/green voltage wires in the earth cable must be 3cm longer than the
others.
The oven must be connected directly to the mains and must have an easily accessible switch
from the start ,installed for the device according to the national, international and local laws in
the country where it is installed. This switch must separate polarization guaranteeing complete
disconnection in accordance with the overvoltage III category.
Correct earthing is obligatory and the earth wire must not be operated by the protection switch.
CABLE CONNECTION
Proceed as follows to connect the power supply wire to the terminal board:
( A1 ) Loosen the tops of the cable gland and open the bottom part of the back of the
appliance by loosening the screws.
( A2 ) Feed the new cable through the cable gland. Connect the cable voltage to the
terminal strips following the connection diagram on the label on the back of the appliance.
Only connect what is indicated inserting the copper bridge and the electricity cable
together under the screws, in the tightening direction, so the cable and the bridge are
tightly fixed by tightening the screw. The type of cable to be used (HO7RN-F) is indicated
on the label for each connection and the voltage sections in mm².
( A4 ) Close the bottom part of the back of the appliance by tightening the screws and fit
the cable by tightening the cable gland top.
Erroneous connection could lead to overheating of the terminal board which could lead to
blowout and electric shock.
Check that all the connections are tight before connecting the oven to the mains.
PE = Yellow/Green: "EARTH" protection conductor.
N = Blue: neutral conductor.
L1, L2, L3 = Brown, Grey, Black: live conductors
E n g l i s h
| 4
Tabla de contenido
loading

Este manual también es adecuado para:

Tpi 07 dc.vTpi 12 dc

Tabla de contenido