E n g l i s h
| 3
IV. PREPARING FOR INSTALLATION
Remove the outer packaging (wooden or carton box) and dispose it in compliance with the
laws in force in the country of installation.
REMOVING PROTECTIVE FILM ETC.
Remove the protection film from the
external and internal walls. (See
image)
Remove all information covering
from the inside, and take off all
plastic packaging.
STAND ADJUSTMENT
Do not use the appliance without feet.
The adjustable feet are already screwed to the underside of the oven.
If they are not used, this prevents airflow from cooling the electric parts and outsides of the
oven which causes over-heating and damage to components.
The oven will function correctly if placed level on a flat surface by adjusting the feets
accordingly and using a spirit level. Screw or unscrew them as necessary to adjust.
V.
ELECTRICAL CONNECTION
WARNING: Mains connection must be carried out by a qualified and authorized
technician according to national, international and local laws in the country where it is
installed. Before mains connection, ensure that the frequency (.....V) and voltage
(....Hz) meet the requirements indicated in the in the information tag on the back of the
appliance.The electric system, as prescribed and specified by the Standard in force, must be
equipped with an efficient ground. It is possible to guarantee the electric safety of the
appliance only in the presence of Standard electric system. For direct connection to the
mains, it is necessary to interpose a device between the equipment and the same mains,
sized for the load, that ensure its disconnection. The contacts must have an opening distance
enabling the full disconnection, in conditions of over-voltage category III, per compliance with
installation regulations. This device also must be located in a place and in a manner to be
easily accessible at any moment by the operator.
OVENS WITH CABLE AND SINGLE PHASE PLUGS
For appliance with cable and plug (single phase 220-240V) the plug merely needs to go into
the appropriate socket (the socket must be adapted for the supplied plug and must withstand
the voltage required by the appliance indicated on the information plate). The product must
be positioned so that the plug is always accessible.
The appliance comes with certified cable and plug therefore they must not be tampered with
or modified. Only the cable can be substituted: this must be carried out by a qualified
authorized technician. The earth wire must always be yellow green.