CABLE SUBSTITUTION
This must be carried out by a qualified authorised technician. The earth wire must always
be yellow green.
WARNING: the yellow/green voltage wires in the earth cable must be 3cm longer than
the others.
Proceed as follows to connect the power supply wire to the terminal board:
( A1 ) Loosen the tops of the cable gland and open the bottom part of the back of the
appliance by loosening the screws.
( A3 ) Loosen the terminal screws and feed the cable conductors through. Take out the
old cable from the cable gland.
( A2 ) Feed the new cable through the cable gland. Connect the new cable's conductors
to the terminal following the connection diagram on the label at the lower part of the back
of the appliance. Only connect what is indicated inserting the copper bridge and the
electricity cable together under the screws, in the tightening direction, so the cable and
the bridge are tightly fixed by tightening the screw. The type of cable to be used (HO7RN-
F) is indicated on the label for each connection and the voltage sections in mm².
( A4 ) Close the bottom part of the back of the appliance by tightening the screws and fit
the cable by tightening the cable gland top.
Check that all the connections are tight before connecting the oven to the mains.
WARNING: Erroneous connection could lead to overheating of the terminal board which
could lead to blowout and electric shock.
Check there is no static discharge between live and earth. Check the limit switch continuity
between the external casing and the earth wire of the mains. It is advised to use a multi tester
to carry out these operations
The appliance must be connected to the mains using a H07RN-F cable.

EQUIPOTENTIAL CONNECTION

This connection shall be carried between the different appliances with
the terminal marked by the symbol: (see image).
This terminal enables the connection of Yellow/Green cable with a
section between 2.5 and 10mm² .
The appliance shall be included in an equipotential system whose
efficiency shall be duly verified according to the provisions of the laws
in force.
VI.

WATER CONNECTION

Make sure the device is placed near a
water connection. Before connecting the
device, allow enough water through to
remove any remnants in the piping so that
they did not get into the magnetic valves.
On the back of the device, in the
areamarked with a label, the convection
oven has an input G 3/4'' with a filter.