• Equipped with ventilation intake from outside.
• Equipped with 230V 50 Hz power supply with an EC compliant earth system.
The product must be connected to a chimney or an internal or external vertical duct that complies with the
regulations in force. The product must be positioned in such a way that the electrical socket is accessible.
EN
3.3

THE OPERATING ENVIRONMENT

In the case of presence of other heating appliances, appropriate air inlets must provide appropriate air
flow for the proper running of each appliance.
In case that in the place where the appliance is installed, other extraction funs (for example exhaust fans)
are present and running, disease can be caused because of the lack of combustion air.
3.4

MINIMUM DISTANCES

If the walls are not flammable place the stove at a minimum rear distance of at least 10 cm. In case of
flammable walls keep the stove at a minimum rear distance (A) of 5 cm, lateral (B) of 10 cm, minimum
distance from the pipe to the wall (E) 50 and front distance of 100 cm.
In case of presence of object considered flammable such as pieces of furniture, curtains and sofas the
distance from the stove must considerably be increased,
TYPE
AQUOS 15-22
IDRON
54
IMPORTANT!
The product must be connected to a chimney or a vertical duct that can expel the
smoke at the highest point of the building.
In any case smoke derives from combustion of types of wood and if it comes in contact
with or close to walls, these can become dirty. Moreover, utmost attention is required
as they are almost invisible but very hot and can cause burns. The holes of the external
air inlet and the smoke outlet pipe must be drilled before positioning the product.
The installation of the product is not allowed in bedrooms, bathrooms or in rooms where
it has already been installed another heating appliance without independent air inlet
(fireplace, stove, etc.).
It is forbidden to install the product in places with explosive athmosfere.
The floor where the appliance is installed must be properly dimensioned in order to
bear its weight.
The ambient ventilation can be adjusted towards the rear wall only in case of the
presence of a proper duction insulated from hot air flow.
If the floor is made of wood, it is recommended to place a floor protection in accordance
with the Standards in force in the country of installation.
NON-FLAMMABLE WALLS
A = 5 cm
B = 5 cm
Fig. 3 - Distances to follow
FLAMMABLE WALLS
A = 10 cm
B = 10 cm
AQUOS - IDRON