ANOMALY
The convection air fan never stops.
(IF PROVIDED)
EN
In the automatic position the stove
always runs at full power.
The product does not start.
No increase in temperature with
stove in operation.
Condensation in boiler.
Radiators cold in winter.
90
POSSIBLE CAUSES
Faulty or malfunctioning temperature
control probe.
Faulty fan.
Silencer card of fan defective.
Thermostat is set to minimum.
The room thermostat is in the
maximum position.
Faulty temperature probe.
Faulty or malfunctioning control
panel.
No power supply.
Pellet temperature probe triggered.
Blown fuse.
Pressure switch broken (lockout
indicated).
Water temperature probe triggered.
Clogged smoke exhaust or smoke
duct.
Incorrect combustion adjustment.
Boiler/system dirty.
Insufficient stove power.
Poor pellets quality.
Incorrect temperature setting.
Insufficient fuel consumption.
Room thermostat (local or remote)
set too low. If remote thermostat,
check if it is defective.
Circulator does not run because
blocked.
Circulator does not run.
Radiators have air in them.
SOLUTIONS
Check the probe and replace it, if
necessary.
Check the operation of the motor
and replace if necessary.
Replace silencer card.
Set the thermostat temperature
again.
Set the thermostat temperature
again.
Check the probe and replace it, if
necessary.
Check the panel and replace it, if
necessary.
Check that the plug is inserted and
the main switch is in the "I" position.
Check recipe parameters.
Replace the fuse.
Water pressure low in stove.
Contact the service centre.
Clean the smoke exhaust and/or the
smoke duct.
Check recipe.
Check and clean the boiler.
Check that the stove is properly sized
for the requirements of the system.
Use of manufacturer pellets.
Set the stove to a higher
temperature.
Check recipe.
Set it at a higher temperature or
replace it (if remote).
Free up the circulator by removing
the plug and turning the shaft with a
screwdriver.
Check the electrical connections of
the circulator; replace if necessary.
Bleed the radiators.