PERIODIC CLEANING PERFORMED BY A QUALIFIED TECHNICIAN

13.6

CLEANING THE HEAT EXCHANGER

Half-way through the winter season, but especially at the end of it, the compartment through which the
exhaust smoke passes will need to be cleaned. This cleaning process is mandatory in order to facilitate the
general removal of all combustion residue, before it becomes very difficult to remove it due to the humidity
compacting it over time.
ATTENTION: For your safety, the frequency with which the exhaust smoke system is
cleaned depends on the intensity of use of the stove.
13.7

CLEANING THE EXCHANGER AND PIPE UNIT

13.8

CLEANING THE UPPER COMPARTMENT

When the stove is cold, remove the top, remove the ceramics/sides, by loosening the relative fastening
screws before removing the drivers "B" and then remove the boiler cover "C" At this point, remove the
four turbulators "D" and using a rigid rod or a bottle brush, clean the internal pipe unit and the turbulators,
removing all of the accumulated ash.
Check the cover gasket and replace it if necessary.
ATTENTION: It is advisable to carry out the cleaning of the upper exchanger at the end
of the season and possibly by an authorised technician in order to replace the gasket
that is below plug "C". (Fig. 29 a pag. 86).