WATER TEMPERATURE PROBE

If the water temperature approaches the shutdown temperature (85°C) the probe makes the boiler
perform the "OFF Stand-by" automatic shutdown.
12.7

ELECTRICAL SAFETY

The product is protected against sudden current surges by a main fuse in the power supply panel on the
rear part of the product. Other fuses that protect the electronic boards are found on the latter.
12.8

SMOkE FAN

If the fan stops, the electronic board promptly shuts off the pellets supply and an alarm message is displayed.
12.9

GEAR MOTOR

If the gear motor stops, the boiler will continue to run until the flame goes out due to lack of fuel and until
a minimum level of cooling is reached.
12.10

TEMPORARY POWER CUT

If the power cut lasts less than 10" the boiler returns to its previous operating status; if it lasts more it carries
out a cooling/restart cycle.
12.11

FAILED START-UP

If during ignition no flame develops, the boiler will go into alarm condition.
12.12

ANTIFREEZE FUNCTION

If the probe in the boiler detects a water temperature of less than 5°C, the circulation pump is automatically
activated to prevent the system from freezing.
12.13

PUMP ANTI-SEIZURE FUNCTION

If the pump is not used for prolonged periods, it is activated periodically for a few seconds to prevent it
from seizing up.
TAMPERING WITH THE SAFETy DEVICES IS PROHIBITED
If the product is NOT used as described in this instruction manual, the manufacturer
declines all liability for any damage caused to persons and property. The manufacturer
furthermore refuses to accept responsibility for damage to persons and property arising
from the failure to observe all the rules contained in the manual and in particular:
• All the necessary measures and/or precautions must be adopted when performing
maintenance, cleaning and repairs.
• Do not tamper with the safety devices.
• Do not remove the safety devices.
• Connect the product to an efficient smoke expulsion system.
• Verify that the room in which the appliance will be installed is adequately ventilated.
The product can be started-up and the automatic function of the probe restored only
after having eliminated the cause that triggered the safety system. This manual will help
you understand which anomaly has occurred, and explain how to intervene according
to the alarm message displayed on the appliance.