fC.y. = 1 the light switches off only with closed automation after tC.y. seconds tC.y.
fC.y. = 2 lighted on for tC.y. seconds from the beginning of a movement, indipendently on the conditions of the automation (the light could
switch off before the end of the movement).
fC.y. = 3 open automation light - the light switches off immediately when the automation reaches the closed position.
fC.y. = 4 open automation light with proportional blinking:
– Opening: slow blinking.
– Closing: fast blinking
– Opened: light on
– Closed: light off.
– Stopped: 2flash + long wait + 2flash + long wait +...
18. COURTESY LIGHT TIME tC.Y.
Activation time of the courtesy light.
19. DEAD MAN DE.A.
During the DEAD MAN functioning mode the automation moves only with a permanent command.
The enabled commands are OPEN and CLOSE. SS and PED are disabled. During the dead man functioning all the automatic movements are disabled,
like short or total inversions. All safety devices are disabled except for STOP.
20. SETTING THE CYCLES THRESHOLD FOR ASSISTANCE REQUEST SE.R.
It is possible to set a number of cycles before the request of assistance. Once the limit is reached, the next cycles will be done with a fast blinking
(only if fp.r. = 1 ).
21. CONTINUOUS FLASHING LIGHT FOR ASSISTANCE REQUEST SE.F.
Once the limit se.f. is reached the flashing light will blink also with the automation closed to show the request of assistance.
22. WATER-HAMMER IN OPENING PHASE HA.o.
This function is used with an electrical lock that has to be enabled by the menu EL.M. The gate presses briefly on the mechanical stop to allow the
disengagement of the electrical lock before an opening movement, starting from a closed gate. By the menu it is possible to set the duration of the
pressure from a minimum of 0,1s to a maximum of 10s.
23. WATER-HAMMER IN CLOSING PHASE HA.c.
This function is used with an electrical lock that has to be enabled by the menu EL.M. When the gate reaches the closing mechanical stop, the control
unit perform a strong pressure, to ensure the locking of the electrical lock. By the menu it is possible to set the duration of the pressure from a minimum
of 0,1s to a maximum of 10s.
24. MODE OF USE OF THE
ELECTRICAL LOCK EL.M.
This parameter allows to select the functioning of the ELECTRICAL LOCK output:
EL.M. = 0 electrical lock disabled or not installed.
EL.M. = 1 the electrical lock will be enabled in the same time of the motors.
EL.M. = 2 the electrical lock will be enabled 1,5s before the motors.
EL.M. = 3 electromagnetic lock: the lock will be enabled only with the automation in the totally closed position. With an opening command the
lock will be disabled. During the function "pressure of the motor in closed position", the electromagnetic lock will be disabled.
WARNING - with the electromagnetic lock it is absolutely necessary the use of the R1 card.
25. MODE OF USE OF THE R1 OUTPUT RI.M.
This parameter allows to select the functioning of the R1 card (optional):
rI.m. = 0 the output is disabled.
rI.M. = 1 electrical lock: the NO contact (without voltage) of the R1 card has the same functioning of the output
rI.m. = 2
courtesy light: the NO contact (without voltage) of the R1 card has the same functioning of the output OPEN GATE LIGHT.
26. PRESSURE OF THE MOTOR IN CLOSED POSITION, ANTI-WIND FUNCTION MP.r.
This function is used to keep the pressure of the motors on the mechanical stop, performed only with closed automation. The control unit performs 1
minute of closing every mp.r. minutes to keep the pressure on the mechanical stops (for example to compensate the wind).
27. MECHANICAL RELAXATION Mr.E.
Function for the mechanical relaxation of the motor: it is useful on those motors that have the unlock for the manual movement which can remain
locked due to the pressure of the motor on the mechanical stop. When it arrives on the mechanical stop, opening or closing, the motor will do a short
inversion of Mr.E. x 50ms.
NOTE - with MP.r with function enabled (pressure of the motor in closed position), the mechanical relaxation is performed only on the first positioning
on the mechanical stop.
28. ECOMODE FUNCTION EC.o.
This parameter allows to enable the ECOMODE function. See chapter 10.
29. FUNCTION SOFT STOP SF.t.
With the SFt parameter, it is possible to stop the gate in a soft way. This behaviour takes place on all step-by-step and stop commands. SFt determines
a soft stop even in the case of safety intervention.
30. RESTORE DEFAULT SETTINGS DE.F.
With the item of the menu de.f. it is possible to restore the default settings of the control unit. The reset will restore all the parameters of the base
and advanced menu, but doesn't modify the learnt strokes.
Move to de.f. then press and hold the "MENU" button until the display shows a number (for example 0), then release the button.
Select the used motor with the "UP" and "DOWN" buttons:
0: CUSTOM
1: XTILUS
2: INT VS
3: MINIART
4: KINEO 400
5: HYPER