10. AMPLITUDE OF SLOWDOWN LSI
With this parameter it is possible to adjust the amplitude of the slowdown and eventually disable it ( LSI= 0 ). If you need more precise or different
slowdown between opening and closing it is possible to set the parameter LSIon P (personalized) and perform an advanced learning of strokes
providing also the beginning of slowdowns during the learning.
11. ANTI SLIPPING / EXTRA TIME ASL
This parameter is used if the motor slips, the control unit adds asL seconds to the movement, to ensure a complete movement of the automation
also in the worst conditions.
12. NUMBER OF MOTORS nMT
This parameter is used to set the number of motors: the learning operations and the functionality will be modified depending on this parameter.
9 - CHANGE PARAMETERS - ADVANCED MENU
This menu allows a more detailed setting of some parameters.
To enter the ADVANCED MENU, press and hold the "MENU" button for at least 5 seconds.
To change the parameters, proceed as described for the BASIC MENU.
WARNING - after 2 minutes of inactivity, the control unit exits automatically from the menu.
PARAMETERS
Intervention mode of the current sensor:
0 = disabled.
sn
m
1
1 = complete (end of the movement and obstacle).
.
.
2 = only obstacle detection in any point of the stroke.
3 = only end of the movement in any point of the stroke.
MI
a
2
Amplitude of the resync area.
.
.
sI
t
3
Intervention time of the current sensor.
.
.
sd
t
4
The disabling time of the current sensor during the start of the motor.
.
.
Acceleration ramp amplitude:
0...20 = ramp amplitude.
ur
a
5
.
.
SSr = single step at 50% of the running speed.
Hsr = single step at 100% of the running speed.
dr
a
6
Deceleration ramp amplitude.
.
.
Functioning of closing photocell (PH1) moving from closed:
sp
h
7
0 = check PH1.
.
.
1 = the automation opens also with PH1 obscured.
Functioning of opening photocell PH2
ph
2
8
0 = enabled in opening and closing.
.
.
1 = enabled only in opening.
Photocells test:
0 = disabled.
tp
h
9
1 = enabled PH1.
.
.
2 = enabled PH2.
3 = enabled PH1 and PH2.
Safety edge type:
ed
m
10
0 = contact (NC).
.
.
1 = resistive (8k2).
Operation mode of safety edge:
0 = working only in closing with inversion of movement.
ie
d
11
.
.
1 = stops the automation (both opening and closing) and free the obstacle
(short inversion).
Safety edge test:
te
d
12
0 = disabled.
.
.
1 = enabled.
LP
o
13
Partial opening.
.
.
6-1622420
rev.5
DESCRIPTION
ITA
14/09/2021
2
2
ENG
FRA
ESP
TUR
DEFAULT
MIN
MAX
CUSTOM
1
0
3
60
0
100
2
1
10
15
0
30
10
0
20
10
0
20
1
0
1
0
0
1
0
0
3
0
0
1
0
0
1
0
0
1
30
0
100
NLD
UP
DOWN
MENU
SS
UNIT
x 100ms
x 100ms
x 35ms
x 35ms
%
17/24
Tabla de contenido
loading

Tabla de contenido