Allmatic BIOS2 24V Manual Del Usuario página 28

Cuadro de mando para cancelas a hoja 24v
Ocultar thumbs Ver también para BIOS2 24V:
Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 74
3.2 - MODELS AND TECHNICAL FEATURES
CODE
DESCRIPTION
12006661
BIOS2 24V control unit for two motors
60551000
Transformer 230 / 23 Vac 150VA
60551040
Transformer 230 / 23 Vac 300VA, for INT VS motors.
12006730
Bluetooth module
12000760
R1 card
12000780
Battery charger 24CBA card
Transformer power supply
Fuse for transformer protection
BIOS2 24V power supply
Maximum power of the motor output
Flashing light output
Courtesy light / Open automation light output
Electrical lock output
24Vdc accessories power supply
433MHz radio receiver
Memorisable transmitters
Operating temperature
3.3 - LIST OF THE SUGGESTED CABLES
The suggested cables for the connection of the various devices in a standard system are listed in the following list.
The used cables must be suitable for the type of installation; for example, an H03VV-F type cable is recommended for indoor applications, while
H07RN-F is suitable for outdoor applications.
Connection
Line for the power supply
Motor
Flashing light
Courtesy light / Open automation light
Electrical lock
Photocells - transmitter
Photocells - receiver
Safety edge
Key selector
* If the cable is more than 10 m long, it must be of larger gauge and a safety grounding system must be installed near the automation unit.
3.4 - PRELIMINARY CHECKS
- The gate shall move frictionless.
Note: Gate features must be uniformed with the standards and laws in force. The door/gate can be automated only if it is in a good condition and if
its conditions comply with the EN 12604 norm.
- The door/gate leaf should not have a pedestrian opening. In the opposite case it is necessary to take the appropriate steps, in accordance with
EN 12453 norm (for instance: by preventing the operation of the motor when the pedestrian opening is opened, by installing a safety microswitch
connected with the control panel).
- Must not generate points of entrapment (e.g. between the leaf of the opened gate and the fence).
- No mechanical stop shall be on top of the gate, since mechanical stops are not safe enough.
Note: the leaf must be fixed firmily on the hinges to the pillars, must not be flexible during the movement and must move without frictions.
4/24
Cable
3 x 1,5 mm 2
2 x 1,5 mm 2
2 x 0,5 mm 2
2 x 0,5 mm 2
2 x 1,0 mm 2
2 x 0,5 mm 2
4 x 0,5 mm 2
2 x 0,5 mm 2
4 x 0,5 mm 2
ITA
ENG
FRA
ESP
230Vac 50-60Hz
T 1A
24Vac 50-60Hz
240W
24Vac 25W
24Vac 25W
12Vac 15VA
24Vdc 5W
Rolling Code
1000
-10°C +55°C
Maximum lenght
20 m *
10 m *
20 m
20 m
10 m
20 m
20 m
20 m
20 m
TUR
NLD
6-1622420
rev.5
14/09/2021
Tabla de contenido
loading

Tabla de contenido