•
Attach the black ring terminal (-) to the negative terminal of the battery.
•
Plug the ring terminal's connector into the connector attached to the
1562A
•
Follow charging instructions as outlined in section 10.
10.
OPERATING INSTRUCTIONS
10.1
Set the 6 and 12 volt selector switch to match the voltage of the battery
being charged.
10.2
Connect charger to a battery as outlined in
10.3
Plug AC power cord into 120 AC volt receptacle.
10.4
The YELLOW LED indicates CHARGING, the GREEN LED indicates
battery is fully CHARGED and the RED LED indicates CHECK BATTERY.
See more detailed explanation below.
10.5
When the charger is plugged into an AC outlet, but not connected to a
battery, the GREEN LED will illuminate. For proper operation, the battery
charger must be plugged into an AC outlet and connected to a battery.
10.6
When properly connected, the YELLOW LED indicator will illuminate. This
indicator will stay illuminated until the battery is fully charged. (The battery
is fully charged when battery voltage reaches approximately 14.4V.) At
that point, the YELLOW LED turns off and the GREEN LED illuminates.
10.7
When the battery is fully charged, the battery charger is in Maintain Mode
which allows the battery charger to keep the battery charged at approxi-
mately 13.2V.
10.8
Never leave the battery connected to the charger while the charger is
unplugged from the AC outlet.
10.9
The RED LED indicates an overload condition. Disconnect clamps for at
least five seconds. Re-connect clamps, and the charger will automatically
reset to the normal charge state.
10.10
Common causes for overload:
•
shorting of the battery clamps
•
reverse-polarity connection to a battery (battery clamps should be in a:
+/+ and -/- connection, instead of +/- connection).
•
problem battery
•
charging two or more batteries in parallel
•
charging batteries larger than the size commonly used in a car or small
truck.
10.11
Battery types: Most Regular, Deep Cycle and Gel Type batteries can be
maintained.
Section 6 or 7.
6
•
•