Ubicación Habitual De Los Componentes; Vista General; Heating Capacity; Air Flow Minimum - Trane Sintesis Balance CMAF 080 Instalación Funcionamiento Y Mantenimiento

Tabla de contenido
Ubicación habitual de los componentes

Vista general

Ventiladores AC o
FWD
Power supply
EC en la plataforma
Capacities
de los ventiladores
Cooling capacity on water (1)
Heating capacity on water (2)
Fan motor
Fan power input (3)
Batería de
Current amps (3)
tubo y
Start-up amps
aleta
Air flow
minimum
nominal
Pantalla
maximum
Main coil
de la
Water entering/leaving connections
unidad
Electric heater (accessory for blower only)
Electric power supply
Panel de

Heating capacity

Hot water coil (accessory for blower only)

control
Heating capacity (4)
G2 filter (filter box accessory)

Quantity

Dimensions ( LxWxth)
G4 filter (filter box accessory)
Quantity
Dimensions ( LxWxth)
Condensate pump (accessory)
Water flow - lift height
Not available for FWD30 and FWD45
Sound level (L/M/H speed)
Sound pressure level (5)
Sound power level (5)
Unit dimensions
Width x Depth
Height
Vista superior (con bombas, depósito de inercia de agua enfriada)
Shipped unit dimensions
Width x Depth
Height
Weight
Colour
Recommended fuse size
Filtro de módulo
Unit alone (aM/gI)
hidrónico de
Unit with electric heater (gI)
agua caliente
(1) Conditions: Water entering/leaving temperature: 7/12 °C, Air inlet temperature 27/19°C DB/WB - Nominal air flow
(2) Conditions: Water entering/leaving temperature: 50/45 °C, Air inlet temperature 20°C DB - Nominal air flow
(3) At high speed with nominal air flow.
Módulo hidrónico
(4) Water entering/leaving temperature 90/70 °C, air inlet temperature 20 °C DB, Nominal air flow.
(5) A rectangular glass wool duct 1m50 long is placed on the blower.The measurement is taken in the room containing the blower unit.
de agua caliente
Heat exchanger operating limits:
(opcional)
FWD:
*water temperature: max 100° C
*absolute service pressure: min 1 bar/max 11 bars
Accessories - Hot water coil:
*water temperature: min. +2° C/max. 100° C
*absolute service pressure: min 1 bar/max 11 bars
Panel de control
4
26
Technical Data
(V/Ph/Hz)
(kW)
(kW)
(type)
(kW)
(A)
(A)
(m
/h)
3
(m
/h)
3
(m
/h)
3
(type)
(Dia)
(V/Ph/Hz)
230/1/50
(kW)
(kW)
(mm)

386x221x8

(mm)
(type)
(l/h - mm)
Panel de control
del ventilador AC
(dB(A))
36/40/43
(dB(A))
46/50/53
(mm)
890 x 600
(mm)
(mm)
933 x 644
(mm)
(kg)
Intercambiador
(A)
de agua caliente
(A)
16 (2kW),25 (4kW)
Compresores
scroll
08
12
5,2
8,3
6,3
11,9
0,23
0,46
1,1
2,2
3,2
5,5
490
980
820
1650
980
1970
3/4"
3/4"
230/1/50 or 400/3/50
2/4
8
6,3
12
2
2

486x271x8

-
2
-
486x264x48
Compresores scroll
38/41/44
48/51/54
1090 x 710
250
300
1133 x 754
260
310
32
46
8/16
8/16
Colector
40 (230V),3*16 (400V)
de líquidos
Depósito de inercia
de agua enfriada
20
30
230/1/50
15
18,8
18,9
20,9
2 x direct drive centrifugal
0,65
1,04
3,1
4,7
9,3
14,1
1400
1800
2300
3000
2600
3600
ISO R7 rotating female
1 1/2"
1 1/2"
400/3/50
400/3/50
10
12
17,4
22,4
2
2
Colector de la tubería
586x321x8
586*421*8
de descarga
2
2
Colector de la tubería
586x314x48
586*414*48
Centrifugal
de aspiración
24 - 500
46/50/53
47/52/57
56/60/63
57/62/67
1290 x 820
1290 x 970
350
450
1333 x 864
1333 x 1008
360
460
61
76
galvanised steel
8/16
8/25
Intercambiador de agua
3*20
3*25
enfriada
Módulo hidrónico
de agua enfriada
(opcional)
Filtro de módulo
hidrónico de agua
enfriada
Vaso de
expansión de
agua enfriada
45
30,1
38,2
1,51
5,5
16,5
2700
4500
5400
1 1/2"
400/3/50
12
34,5
2
586*621*8
2
586*614*48
47/52/58
57/62/68
1290 x 1090
650
1333*1133
660
118
8/25
3*25
UNT-PRC002-GB
CG-SVX051A-ES

Hide quick links:

Tabla de contenido
loading

Tabla de contenido