Tabla De Contenido - Trane Sintesis Balance CMAF 080 Instalación Funcionamiento Y Mantenimiento

Tabla de contenido
Índice
INFORMACIÓN GENERAL ................................................................................ 4
DESCRIPCIÓN DE LA UNIDAD ......................................................................... 6
FWD
Power supply
DESCRIPCIÓN DE LOS NÚMEROS DE MODELO DE LA UNIDAD ................. 7
Capacities
Heating capacity on water (2)
Fan motor
CONSIDERACIONES PREVIAS A LA INSTALACIÓN ....................................... 9
Start-up amps
DATOS GENERALES ........................................................................................ 11
nominal
TABLA 1: UNIDADES CMAF 080-100, VERSIÓN CORTA DE RENDIMIENTO
maximum
Main coil
ESTÁNDAR .............................................................................................................11
Water entering/leaving connections
TABLA 2: UNIDADES CMAF 080-130 DE RENDIMIENTO ESTÁNDAR ............. 14
Electric heater (accessory for blower only)
Electric power supply
TABLA 3: UNIDADES CMAF 140-190 DE RENDIMIENTO ESTÁNDAR ............. 17
Heating capacity (4)
TABLA 4: UNIDADES CMAF 080-130 DE ALTA EFICIENCIA ............................. 20
G2 filter (filter box accessory)
Quantity
TABLA 5: UNIDADES CMAF 140-190 DE ALTA EFICIENCIA .............................. 23
Dimensions ( LxWxth)
G4 filter (filter box accessory)
UBICACIÓN HABITUAL DE LOS COMPONENTES ........................................ 26
Condensate pump (accessory)
Water flow - lift height
REQUISITOS DE INSTALACIÓN ..................................................................... 28
Not available for FWD30 and FWD45
Sound level (L/M/H speed)
Sound pressure level (5)
Sound power level (5)
TUBERÍAS DE AGUA ENFRIADA/CALIENTE ................................................. 30
Unit dimensions
TABLA 6: CAUDAL DE DESCONEXIÓN MÍNIMO Y MÁXIMO ........................... 32
TABLA 7: CAUDAL DE DETECCIÓN MÁXIMO SEGÚN EL DIÁMETRO
DE LA TUBERÍA .................................................................................................... 32
Recommended fuse size
TABLA 8: CALOR ESPECÍFICO DE LA SALMUERA (KJ/KG)
AL 30% DE CONCENTRACIÓN ........................................................................... 34
(1) Conditions: Water entering/leaving temperature: 7/12 °C, Air inlet temperature 27/19°C DB/WB - Nominal air flow
TABLA 9: ETAPA DEL COMPRESOR MÁS ALTA ................................................ 34
(2) Conditions: Water entering/leaving temperature: 50/45 °C, Air inlet temperature 20°C DB - Nominal air flow
(3) At high speed with nominal air flow.
TABLA 10: CAPACIDAD DE AGUA HABITUAL NORMAL (M 3 ) INCLUIDO
(4) Water entering/leaving temperature 90/70 °C, air inlet temperature 20 °C DB, Nominal air flow.
(5) A rectangular glass wool duct 1m50 long is placed on the blower.The measurement is taken in the room containing the blower unit.
EL DEPÓSITO DE INERCIA .................................................................................. 34
Heat exchanger operating limits:
*water temperature: max 100° C
*absolute service pressure: min 1 bar/max 11 bars
ENFRIADA/CALIENTE ..................................................................................... 36
TABLA 11: NÚMERO DE PLACA DEL INTERCAMBIADOR DE AGUA
ENFRIADA/CALIENTE DE LAS UNIDADES CMAF ............................................. 36
CONJUNTO DE LA BOMBA INTEGRADA ..................................................... 37
PRESIÓN DISPONIBLE DE LA BOMBA INTEGRADA ................................... 40
2
4
© Trane 2020
Technical Data
08
(V/Ph/Hz)
5,2
(kW)
6,3
(type)
0,23
1,1
3,2
(m
/h)
490
3
(m
/h)
820
3
(m
/h)
980
3
3/4"
(V/Ph/Hz)
230/1/50
(kW)
2/4
(kW)
6,3
2
(mm)
-
(mm)
-
(type)
(l/h - mm)
(dB(A))
36/40/43
(dB(A))
46/50/53
(mm)
890 x 600
(mm)
250
(mm)
933 x 644
(mm)
260
32
(A)
8/16
(A)
16 (2kW),25 (4kW)
12
20
230/1/50
8,3
15
11,9
18,9
0,46
0,65
2,2
3,1
5,5
9,3
980
1400
1650
2300
1970
2600
3/4"
1 1/2"
230/1/50 or 400/3/50
400/3/50
8
10
12
17,4
2
2
586x321x8
2
2
486x264x48
24 - 500
38/41/44
46/50/53
48/51/54
56/60/63
300
350
1133 x 754
1333 x 864
310
360
46
61
8/16
8/16
40 (230V),3*16 (400V)
3*20
30
45
18,8
30,1
20,9
38,2
1,04
1,51
4,7
5,5
14,1
16,5
1800
2700
3000
4500
3600
5400
1 1/2"
1 1/2"
400/3/50
400/3/50
12
12
22,4
34,5
2
2
586*421*8
586*621*8
2
2
586*414*48
586*614*48
47/52/57
47/52/58
57/62/67
57/62/68
450
650
1333 x 1008
1333*1133
460
660
76
118
8/25
8/25
3*25
3*25
UNT-PRC002-GB
CG-SVX051A-ES

Hide quick links:

Tabla de contenido
loading