Status
3 LEDs light.
2 LEDs light.
1 LED lights.
1 LED blinks, the appliance is ready for use.
1 LED blinks, the appliance is not ready for use.
4 LEDs blink, the appliance is not ready for use.
Battery state of charge cannot be displayed while the control switch is pressed and for up to 5 seconds
after releasing the control switch.
If the battery charge state LEDs blink, please refer to the information given in the Troubleshooting
section.
3.6
Indication of overloading and overheating
The power tool is equipped with an electronic system to protect against overloading and overheating. The
power tool switches itself off automatically in the event of overloading or overheating. After releasing the
control switch, the power tool may not restart immediately when the switch is pressed again (while the power
tool is cooling down).
4

Technical data

Rated voltage (DC)
Rated current input
Weight in accordance with EPTA-Procedure 01 (measured with B22⁄5.2)
Ambient temperature
Storage temperature
4.1
Noise and vibration information, measured in accordance with EN 60335-2-69
Sound pressure level (L
Sound power level (L
WA
Uncertainty
Vibration emission value (a
Uncertainty (K)
5
Operation
5.1
Preparations at the workplace
Observe the safety instructions and warnings in this documentation and on the product.
WARNING The appliance may be operated only by authorized, trained personnel.
5.1.1
Charging the battery
1. Before charging the battery, read the operating instructions for the charger.
2. Make sure that the contacts on the battery and the contacts on the charger are clean and dry.
3. Use an approved charger to charge the battery.
14
English
)
pA
)
)
h
Meaning
State of charge: 50 % to 75 %
State of charge: 25 % to 50 %
State of charge: 10 % to 25 %
State of charge: < 10 %
The battery has overheated.
The appliance has overheated or is overloaded.
2190975
*2190975*
VC 5-A22
21.6 V
16 A
5.2 kg
−17 ℃ ... 60 ℃
−20 ℃ ... 70 ℃
VC 5-A22
70.9 dB(A)
85.2 dB(A)
2.4 dB(A)
< 2.5 m/s²
Is taken into account in
the stated value
Tabla de contenido